Tech & Reviews

CPS PCCOOLER YT1000 PSU Review: Specifications and Power Performance

Hardware Busters reviews the YT1000 power supply, discussing hardware design, stated specifications and power-delivery performance. Read the original third-party article for the measurement setup, supporting results and any noted limitations.

CPS PCCOOLER YT1000 ATX v3.1 PSU Review

The YT1000 carries Cybenetics Platinum efficiency and ATX 3.1 compliance results. Short-duration excursion support is separate from its 1000 W continuous rating. The assessment applies to the reviewed sample.

The CPS PCCOOLER YT1000 is (or will be) included in my best ATX v3.x & PCIe 5.x PSU picks article.

The source identifies CPS PCCOOLER as the component brand of Shenzhen Fluence Technology, with products spanning coolers, fans, power supplies and lighting. It also notes the company's Chinese listing under stock code 300647 at the time of the article.

The CPS PCCOOLER YT line consists of three models with maximum power ratings of 850W, 1000W, and 1200W. All are certified by Cybenetics, and in today’s review, I will evaluate the middle member of the line.

The source reports Cybenetics Platinum and ATX 3.1 results; no retail price was available at publication.

YT1000 PSU Review: Specifications and Power Performance Check out our top ATX v3.1 PSU guide before purchasing your next PSU.

ATX v3.x 1000W PSU Reviews:

Cybenetics PSU Test Database Best ATX v3.x PSUs

Power Specifications

Rail 3.3V 5V 12V 5VSB -12V
Max. Power Amps 20 20 83.3 3 0.3
Watts 100 999.6 15 3.6
Total Max. Power (W) 1000

Box & Bundle

YT1000 PSU Review: Specifications and Power Performance

I received early samples, so photos of the box are not available at this time. This means I can use any photo I want here. This is a photo of my plane under the moon!

Product Photos

psu_top_front

psu_top_front

psu_front

psu_front

psu_label

psu_label

psu_bottom

psu_bottom

psu_top_rear

psu_top_rear

psu_standby1

psu_standby1

psu_standby2

psu_standby2

psu_standby3

psu_standby3

Triangular openings shape the intake grille and rear exhaust. The AC side includes the inlet, main switch and a separate switch for enabling or disabling fan-stop operation. (YT1000 PSU Review: Specifications and Power Performance)

The modular panel has eleven sockets, including a native 12V-2×6 header.

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (600mm) 1 1 18AWG No
4+4 pin EPS12V (650mm) 2 2 18AWG No
6+2 pin PCIe (600mm) 3 3 18AWG No
12+4 pin PCIe (650mm) (600W) 1 1 16-24AWG No
SATA (445mm+150mm+150mm) / 4-pin Molex (+150mm) 3 9 / 3 18AWG No
AC Power Cord (1380mm) – C13 coupler 1 1 18AWG –
box_cables

box_cables

cable2

cable2

cable3

cable3

cable4

cable4

cable5

cable5

cable6

cable6

cable1

cable1

The cables are long enough, and unlike the YT1200 model, the high-power cables (except 12V-2×6) use the standard AWG18 gauges instead of thicker (AWG16), which would offer lower voltage drops at high loads. The number of peripheral connectors is sufficient, and the distance between them is identical, at 150mm.

Part Analysis

General Data
Manufacturer (OEM) Andyson
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor SCK205R0 (5 ohm) & Relay
Bridge Rectifier(s) 2x GBU1506 (600V, 15A @ 100°C)
APFC MOSFETs 2x Way-on WML53N60C4 (600V, 26A @ 100°C, Rds(on): 0.07Ohm)
APFC Boost Diode Global Power Technology G4S06508AT (650V, 8A @ 153°C)
Bulk Cap(s) 2x Nippon Chemi-Con (420V, 470uF each or 940uF combined, 2000h @ 105°C, KMQ)
Main Switchers 4x Way-On WML26N60F2 (650V, 10.5A @ 100°C, Rds(on): 0.21Ohm)
APFC  Controller Champion CM6500UNX
Resonant Controller Champion CU6901VPA
Topology Primary side: APFC, Full-Bridge & LLC Resonant converter Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 8x Ping Wei PWC012N04ES (40V, 132A @ 100°C, Rds(on): 1.2mOhm)
5V & 3.3V DC-DC Converters: 6 x Way-On WMB050N03LG4 (30V, 41A @ 100°C, Rds(on): 5.4mOhm) PWM Controller(s): ANPEC APW7159C
Filtering Capacitors Electrolytic: 7x Rubycon (4-10,000h @105°C, YXS) 3x Rubycon (6-10,000h @105°C, ZLH) 2x Rubycon (4-10,000h @105°C, YXJ) Nippon Chemi-Con (10,000h @105°C, LE) Teapo (3,000h @105°C, SC) Polymer: 30x Polycap, 1x FPCAP
Supervisor IC Weltrend WT7527 (OCP, OTP, OVP, UVP, SCP, PG)
Fan Controller / Micro Controller Weltrend WT51F104
Fan Model Hong Hua HA13525H12F-Z (135mm, 12V, 0.50, Fluid Dynamic Bearing Fan)
5VSB
Rectifier PJ335M
Standby PWM Controller Excelliance MOS EMB8569C
top1

top1

top2

top2

top3

top3

top4

top4

The Andyson platform uses a full-bridge LLC primary stage, eight +12 V switching devices and a pair of DC-to-DC converters for the minor outputs. The reviewer praises component selection but criticizes soldering on the supplied pre-production samples, also comparing a Sharkoon Rebel P20 on the same platform. Appearance alone does not establish whether joints are electrically or mechanically reliable.

Sharkoon Rebel P20 1000 CPS PCCOOLER YT1000
YT1000 PSU Review: Specifications and Power Performance YT1000 PSU Review: Specifications and Power Performance

Here is a comparison between the Sharkoon Rebel’s P20 PCB and the YT1000’s PCB. As you can see, besides the different PCB colors, there are differences in the soldering and coating quality, with the P20 having a clear advantage. Because some of the YT1000’s parts are not recognizable, I will use some photos of the Rebel P20, where the marking can be distinguished.

transienta1

transienta1

transienta2

transienta2

transientb1

transientb1

transientb2

transientb2

The EMI filter runs from the AC inlet onto the main PCB and includes the components shown in the internal photographs. Its actual effectiveness is evaluated by the later emissions tests.

MOV

MOV

NTC_&_relay

NTC_&_relay

The input stage has a surge MOV and a 5 Ω NTC thermistor, supported by a bypass relay.

bridge_rectifiers1

bridge_rectifiers1

bridge_rectifiers2

bridge_rectifiers2

The two GBU1506 parallel bridge rectifiers can handle up to 50A together.

APFC_FETs

APFC_FETs

boost_diode

boost_diode

bulk_caps

bulk_caps

The APFC converter uses two Way-on WML53N60C4 FETs and one Global Power Technology G4S06508AT boost diode. Nippon Chemi-Con manufactures the bulk capacitors. Their combined capacity is 940 μF, and both are rated for 2,000 hours at 105 °C. The voltage rating is 420V, which is higher than the APFC’s DC bus voltage (approximately 380-400V DC).

YT1000 PSU Review: Specifications and Power Performance

The APFC controller is Champion CM6500UNX.

YT1000 PSU Review: Specifications and Power Performance

Four Way-On WML26N60F2 primary switching FETs are installed in a full-bridge topology, and an LLC resonant converter is utilized for enhanced efficiency.

YT1000 PSU Review: Specifications and Power Performance

The LLC resonant controller is Champion CU6901VPA.

YT1000 PSU Review: Specifications and Power Performance

The main transformer provides electrical isolation between the primary and secondary circuits as part of power conversion.

YT1000 PSU Review: Specifications and Power Performance

Eight Ping Wei PWC012N04ES FETs regulate the 12V rail.

minor_rail_FETs

minor_rail_FETs

PWM_controller

PWM_controller

Two DC-DC converters generate the minor rails. They use six Way-On WMB050N03LG4 FETs. The PWM controller is an Anpec APW7159C .

caps1

caps1

caps2

caps2

caps3

caps3

caps4

caps4

caps5

caps5

Electrolytic capacitors are from Chemi-Con, Rubycon and Teapo; polymer capacitors are from FPCAP and Polycap.

You can find more information about capacitor performance and other specs below:

standby_PWM_controller

standby_PWM_controller

5vsb_transformer

5vsb_transformer

The standby PWM controller is Excelliance MOS EMB8569C.

modular_board1

modular_board1

modular_board2

modular_board2

modular_board3

modular_board3

Polymer capacitors on the modular panel add another output-filtering stage.

main_PCB1

main_PCB1

main_PCB2

main_PCB2

main_PCB3

main_PCB3

The soldering quality is not good, and the same applies to the PCB’s coating.

fan

fan

fan_close

fan_close

The cooling fan is a Hong Hua HA13525H12F-Z, utilizing a fluid dynamic bearing.

Load Regulation

Load regulation measures how output voltage changes as the connected load varies.

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 6.460A 1.996A 1.952A 0.985A 100.022 86.486% 0 <6.0 46.94°C 0.972
12.139V 5.011V 3.381V 5.076V 115.649 40.47°C 114.92V
20% 13.930A 2.996A 2.93A 1.186A 199.982 90.873% 0 <6.0 47.83°C 0.986
12.137V 5.009V 3.379V 5.062V 220.069 40.82°C 114.89V
30% 21.782A 3.496A 3.42A 1.387A 300.043 91.929% 0 <6.0 50.69°C 0.986
12.119V 5.007V 3.377V 5.047V 326.384 41.26°C 114.87V
40% 29.600A 3.997A 3.911A 1.59A 399.864 91.991% 0 <6.0 53.38°C 0.987
12.117V 5.005V 3.375V 5.033V 434.676 41.7°C 114.83V
50% 37.073A 5A 4.894A 1.794A 499.613 91.484% 928 27.7 42.29°C 0.985
12.114V 5.002V 3.373V 5.019V 546.119 62.44°C 114.79V
60% 44.617A 6.003A 5.877A 1.999A 600.124 90.96% 925 27.6 42.9°C 0.986
12.110V 5V 3.37V 5.005V 659.771 64.65°C 114.76V
70% 52.086A 7.008A 6.862A 2.204A 699.832 90.415% 921 27.5 43.33°C 0.986
12.109V 4.997V 3.367V 4.991V 774.017 66.14°C 114.73V
80% 59.630A 8.014A 7.847A 2.309A 799.877 89.63% 1519 43.2 43.69°C 0.988
12.108V 4.992V 3.364V 4.981V 892.421 65.59°C 114.71V
90% 67.500A 8.518A 8.328A 2.415A 899.678 88.926% 1515 42.7 44.75°C 0.988
12.107V 4.99V 3.362V 4.97V 1011.723 70.1°C 114.67V
100% 75.154A 9.022A 8.839A 3.036A 999.694 88.137% 1512 42.4 45.91°C 0.989
12.109V 4.988V 3.36V 4.942V 1134.257 74.93°C 114.64V
110% 82.720A 10.029A 9.918A 3.042A 1100.317 87.172% 1509 42.3 46.52°C 0.99
12.113V 4.986V 3.358V 4.933V 1262.23 81.09°C 114.6V
CL1 0.116A 12.049A 11.761A 0A 101.32 82.209% 928 27.7 41.98°C 0.975
12.167V 4.997V 3.376V 5.093V 123.246 62°C 114.91V
CL2 0.115A 20.048A 0A 0A 101.406 80.027% 1524 43.4 40.37°C 0.977
12.154V 4.988V 3.383V 5.099V 126.72 52.93°C 114.91V
CL3 0.116A 0A 19.575A 0A 67.399 77.415% 1239 36.8 40.69°C 0.961
12.047V 5.013V 3.372V 5.099V 87.06 49.83°C 114.92V
CL4 82.689A 0A 0A 0A 1000.178 88.788% 1509 42.3 45.69°C 0.989
12.096V 5.004V 3.369V 5.05V 1126.487 70.69°C 114.64V
regulation_12v_115V

regulation_12v_115V

regulation_12v_230V

regulation_12v_230V

regulation_5v_115V

regulation_5v_115V

regulation_5v_230V

regulation_5v_230V

regulation_33v_115V

regulation_33v_115V

regulation_33v_230V

regulation_33v_230V

regulation_5vsb_115V

regulation_5vsb_115V

regulation_5vsb_230V

regulation_5vsb_230V

Load regulation is within 1% on all primary rails, so all is good here.

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
20W 1.234A 0.499A 0.488A 0.196A 20.008 78.098% 0 <6.0 41.93°C 0.719
12.033V 5.015V 3.384V 5.11V 25.617 36.6°C 114.95V
40W 2.717A 0.698A 0.683A 0.294A 40.004 84.389% 0 <6.0 43.37°C 0.883
12.033V 5.015V 3.384V 5.105V 47.405 37.6°C 114.94V
60W 4.199A 0.898A 0.878A 0.392A 60.003 86.609% 0 <6.0 43.23°C 0.938
12.034V 5.014V 3.384V 5.1V 69.279 38.08°C 114.94V
80W 5.632A 1.098A 1.073A 0.491A 79.969 84.24% 0 <6.0 46.25°C 0.964
12.133V 5.013V 3.382V 5.095V 94.932 39.63°C 114.93V

A glance at the light loads table is always useful, as the PSU will typically operate at light loads.

Ripple Suppression

Ripple is the unwanted AC component superimposed on a DC output. The test measures its amplitude to assess filtering quality and compares the result with the stated limits. Lower ripple is preferable, but this measurement alone does not establish component lifetime.

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 10.4 mV 7.7 mV 6.2 mV 12.6 mV Pass
20% Load 9.0 mV 8.8 mV 7.4 mV 12.6 mV Pass
30% Load 11.3 mV 8.3 mV 7.3 mV 12.8 mV Pass
40% Load 11.1 mV 10.9 mV 9.7 mV 13.5 mV Pass
50% Load 11.5 mV 9.1 mV 8.3 mV 13.3 mV Pass
60% Load 11.8 mV 9.7 mV 9.3 mV 15.0 mV Pass
70% Load 12.0 mV 11.1 mV 10.2 mV 15.8 mV Pass
80% Load 12.9 mV 10.8 mV 13.9 mV 17.0 mV Pass
90% Load 12.4 mV 10.9 mV 14.4 mV 17.4 mV Pass
100% Load 16.7 mV 12.0 mV 15.6 mV 17.7 mV Pass
110% Load 17.5 mV 12.7 mV 17.4 mV 24.3 mV Pass
Crossload 1 10.5 mV 9.3 mV 11.8 mV 8.9 mV Pass
Crossload 2 10.7 mV 8.4 mV 7.1 mV 8.0 mV Pass
Crossload 3 20.4 mV 9.0 mV 12.8 mV 7.9 mV Pass
Crossload 4 16.3 mV 11.4 mV 12.0 mV 10.8 mV Pass
ripple_12v_115V

ripple_12v_115V

ripple_12v_230V

ripple_12v_230V

ripple_5v_115V

ripple_5v_115V

ripple_5v_230V

ripple_5v_230V

ripple_33v_115V

ripple_33v_115V

ripple_33v_230V

ripple_33v_230V

ripple_5vsb_115V

ripple_5vsb_115V

ripple_5vsb_230V

ripple_5vsb_230V

Ripple suppression is very good overall.

Transient Response

Transient response describes voltage deviation and recovery when load changes suddenly. Both the size of the excursion and recovery time matter when comparing the same test pattern.

20% Load – 20ms

Advanced Transient Response 20% - 50 Hz - No Caps
Voltage Before After Change Pass/Fail
12V 12.118V 11.951V 1.37% Pass
5V 5.007V 4.901V 2.12% Pass
3.3V 3.375V 3.217V 4.70% Pass
5VSB 5.067V 5.016V 1.01% Pass

50% Load -20ms

Advanced Transient Response 50% - 50 Hz - No Caps
Voltage Before After Change Pass/Fail
12V 12.083V 11.975V 0.89% Pass
5V 5.001V 4.910V 1.82% Pass
3.3V 3.368V 3.205V 4.84% Pass
5VSB 5.028V 4.985V 0.86% Pass
transient_12v_115V

transient_12v_115V

transient_5v_115V

transient_5v_115V

transient_33v_115V

transient_33v_115V

transient_5vsb_115V

transient_5vsb_115V

The transient response could be more competitive at 12V. It is mediocre on the minor rails.

Transient Response ATX v3.1 Tests

[Note] For PSUs without a 12+4 pin connector, the maximum applied load for the transient response tests is 150%, rather than 200%.

transient_120_dev

transient_120_dev

transient_120_voltage

transient_120_voltage

transient_160_dev

transient_160_dev

transient_160_voltage

transient_160_voltage

transient_180_dev

transient_180_dev

transient_180_voltage

transient_180_voltage

transient_200_dev

transient_200_dev

transient_200_voltage

transient_200_voltage

The PSU passes all ATX v3.1 transient response tests.

transient_120_dev

transient_120_dev

transient_120_voltage

transient_120_voltage

transient_160_dev

transient_160_dev

transient_160_voltage

transient_160_voltage

transient_180_dev

transient_180_dev

transient_180_voltage

transient_180_voltage

transient_200_dev

transient_200_dev

transient_200_voltage

transient_200_voltage

The 12V rail’s performance is above average in these tests.

Hold Up Time

Hold-up time is the interval for which output remains within its specified range after AC input is interrupted. It is measured in milliseconds and helps bridge very brief interruptions; it is not a substitute for a UPS or a guarantee of enough time for an operating-system shutdown.

hold_up_time

hold_up_time

ac_loss_hold_up_time

ac_loss_hold_up_time

pwr_ok_inactive_to_dc_loss_delay

pwr_ok_inactive_to_dc_loss_delay

The hold-up time is extended.

Inrush Current

Inrush current is the brief surge drawn at switch-on as the input capacitors charge. Lower peaks reduce stress on the input path and can help avoid nuisance breaker trips under the same supply conditions.

inrush_current_115V

inrush_current_115V

inrush_current_230V

inrush_current_230V

The inrush currents are at the expected levels, given the capacity of the unit’s bulk caps.

Leakage Current

Leakage current is current flowing through paths other than the intended functional circuit. In PSU testing, the measurement arrangement and the distinction between protective-conductor and touch current must be considered.

In an earthed PSU, EMI-filter Y capacitors contribute AC current to the protective conductor. The measured current depends on capacitance, input voltage, frequency and the test circuit, not simply on the number of capacitors.

The source cites IEC 62368-1 for its leakage and touch-current assessment. Compliance depends on the applicable equipment category and test conditions.

  • Normal Condition: Maximum touch current = 3.5 mA
  • Single Fault Condition: Maximum touch current = 10 mA

YT1000 PSU Review: Specifications and Power Performance

The leakage current is low.

PSU Timings

PSU timing tests check the sequence and duration of startup, power-good and shutdown signals against the stated ATX criteria. These should be read as measured timing behavior, not an independent guarantee against every system fault.

Alternative Low Power Modes concern low-power system operation and transitions between power states. The review examines their associated ATX timing requirements, including T1 and T3.

T1 and T3 Timings Explained

YT1000 PSU Review: Specifications and Power Performance

  • T1 (power-on time) measures the interval from PS_ON# assertion until the main outputs enter regulation. The subsequent PWR_OK delay is T3 and must be assessed separately. Apply the limits for the relevant ATX revision and low-power-mode requirements.
  • T3 (PWR_OK delay) is the interval from the outputs entering regulation until PWR_OK is asserted. It is distinct from T1. Compare results using the criteria for the same ATX revision and operating mode.
timing_20%_t1

timing_20%_t1

timing_20%_t3

timing_20%_t3

timing_100%_t1

timing_100%_t1

timing_100%_t3

timing_100%_t3

The PSU supports Alternative Low Power Modes.

Efficiency Normal, Light & Super-Light Loads

Efficiency is DC output power divided by AC input power. For example, delivering 400 W at 80% efficiency requires 500 W input, leaving 100 W as conversion loss.

avg_efficiency_normal_loads1_115V

avg_efficiency_normal_loads1_115V

avg_efficiency_normal_loads1_230V

avg_efficiency_normal_loads1_230V

avg_efficiency_low_loads1_115V

avg_efficiency_low_loads1_115V

avg_efficiency_low_loads1_230V

avg_efficiency_low_loads1_230V

efficiency_ultra_low_load1_115

efficiency_ultra_low_load1_115

efficiency_ultra_low_load1_230

efficiency_ultra_low_load1_230

High enough average efficiency at normal loads, and pretty high efficiency for light and ultra-light loads.

Average Efficiency

The PSU’s average efficiency with more than 1450 different load levels at 115V and 230V is depicted in the graphs below.

avg_eff_115V

avg_eff_115V

avg_eff_230V

avg_eff_230V

The average efficiency meets the Cybenetics Platinum criteria.

Average PF

Power factor is real power in watts divided by apparent power in volt-amperes. It describes AC input-current behavior and is distinct from conversion efficiency. Active PFC aims to bring it closer to unity.

avg_pf_115V

avg_pf_115V

avg_pf_230V

avg_pf_230V

The APFC converter needs tuning for higher PF readings.

Average Efficiency 5VSB

5VSB_efficiency_115V

5VSB_efficiency_115V

5VSB_efficiency_230V

5VSB_efficiency_230V

The 5VSB rail’s efficiency is satisfactory at 115V, but I would like to see close to 80% also at 230V input.

Vampire Power

Standby input power is drawn while the PSU is connected to AC but not supplying the main system outputs. Functions such as +5VSB remain available. The measurement depends on the standby load and operating state.

Stand_By_115V

Stand_By_115V

Stand_By_230V

Stand_By_230V

Vampire power is below 0.1W at 115V, but notably above this threshold at 230V.

Protection Features

PSU protection tests examine responses to overload and other specified abnormal conditions. The presence of protection circuitry should be distinguished from its measured triggering thresholds and behavior.

OCP (Normal @ 30.6°C) 12V: 112.00A (134.45%), 12.127V 5V: 30.8A (154.00%), 4.971V 3.3V: 29.5A (147.50%), 3.364V 5VSB: 6.2A (206.67%), 4.925V
OCP (Hot @ 44.9°C) 12V: 112.60A (135.17%), 12.130V 5V: 30.8A (154.00%), 4.971V 3.3V: 29.5A (147.50%), 3.364V 5VSB: 6.2A (206.67%), 4.914V
OPP (Normal @ 29.2°C) 1349.98W (135.00%)
OPP (Hot @ 43.0°C) 1198.47W (119.85%)
OTP ✓ (142°C @ Heat Sink)
SCP 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK Proper Operation
UVP (Full Load @ 90V) ✓
UVP (No Damage @ 80V) ✓
Conducted Emissions EN55032 & CISPR 32 ✓
NLO ✓
Fan Failure Protection ✗
SIP Surge: MOV Inrush: NTC & Bypass Relay

Unlike the 1200W model, the OCP triggering points are not correctly set at 12V, since the hot triggering point is higher than the one under normal operating temperatures. Typically, it should be the other way around, since the PSU is stressed more under higher temperatures! Also, similar to the YT1200, the minor rails have high OCP triggering points compared to the nominal ratings, and to make matters worse, there is no difference in the triggering points between normal and high temperatures.

The reviewer considers OPP thresholds appropriately separated between normal and hot conditions. The other listed protections worked in the tests, but fan-failure protection was not implemented in the sample.

EMC Pre-Compliance at a Glance

The source evaluates electromagnetic emissions using CISPR 32/EN 55032 reference limits, including the stricter Class B limits associated with domestic equipment. These pre-compliance measurements do not by themselves establish complete regulatory certification.

Our equipment for EMI readings:

  • Rohde & Schwarz FPC1500 (loaded with all options)
  • Tekbox TBLC08 LISN
  • Tekbox TBFL1 transient limiter
  • Tekbox EMCview software
CISPR 32 / EN55032 Limits
CISPR 32 / EN 55032 Class A Conducted EMI Limit
Frequency of Emission (MHz) Conducted Limit (dBuV)
Quasi-peak Average
0.15 – 0.50 79 66
0.50 – 30.0 73 60
CISPR 32 / EN 55032 Class B Conducted EMI Limit
Frequency of Emission (MHz) Conducted Limit (dBuV)
Quasi-peak Average
0.15 – 0.50 66 – 56 56 – 46
0.50 – 5.00 56 46
5.00 – 30.00 60 50

The review applies the 4 dB margin described in its ATX emissions criteria. Passing that comparison should not be confused with independently demonstrating compliance with every applicable EMC limit.

EMI Results

YT1000 PSU Review: Specifications and Power Performance

EMI pre-compliance results were better controlled than on the tested YT1200.

Average Noise

avg_noise_115V

avg_noise_115V

avg_noise_230V

avg_noise_230V

The PSU’s average noise output is notably lower than that of the YT1200 model.

Fan Noise & Speed Maps @ 28-32 °C – 115V

CL_Fan_Noise

CL_Fan_Noise

CL_Fan_Speed

CL_Fan_Speed

Similar to the YT1200, the fan speed profile map looks like a modern abstract art painting, but overall, it is notably less aggressive. The fan’s passive mode lasts up to 400W at 12V, with the load on the minor rails remaining below 70W. At loads of up to 400W, if you apply more than 70W to the minor rails, the fan’s speed increases, raising the noise level to the 10-15 dBA range, which is not particularly high. For loads higher than 400W, the fan’s noise exceeds 25 dBA if you apply more than 70-75W on the minor rails. The 30 dBA mark is reached at around 710W, and the 30-35 dBA period lasts for a very short time. The dominant noise range for loads exceeding 710W is 35-40 dBA, with a shorter period where the noise exceeds 40 dBA, particularly when the load on the minor rails exceeds 90W. Clearly, the load on the minor rails highly affects noise output, so it would be a good idea for Andyson to use proper heatsinks to keep the corresponding circuit cooler under increased loads.

Fan Noise & Speed Maps @ 28-32 °C – 230V

CL_Fan_Noise

CL_Fan_Noise

CL_Fan_Speed

CL_Fan_Speed

At 230V, the fan speed profile is identical to that of the 115V input.

Overall Performance

Here is the link to read more about this performance algorithm.

perf_115V

perf_115V

perf_230V

perf_230V

The overall performance is competitive, despite the fierce competition in the 1000W category.

Epilogue

The reviewer found competitive electrical results, including regulation, ripple, inrush and hold-up behavior. EMI filtering was better than on the tested YT1200. APFC power factor at 230 V and OCP settings on both +12 V and the minor rails remained concerns, while OPP was considered correctly set.

The fan profile is quieter than the YT1200's on average, but high loading of the DC-to-DC outputs still raises noise. Combined +5 V demand, including ARGB devices, should therefore be considered along with CPU and GPU power.

All in all, the CPS PCCOOLER YT1000 offers competitive overall performance. The only reason I don’t provide a recommendation award is that I decided some time ago not to do so if the protection features (OCP mostly) are not correctly set. Additionally, since I don’t have any pricing information (at the time of the review), I cannot comment on its price-per-performance ratio.

YT1000 PSU Review: Specifications and Power Performance

The original reviewer links to a comparison of ATX v3.x power supplies and discloses that purchases through affiliate links may earn a commission without changing the listed price. (Reference 1)

Buy CPS PCCOOLER YT1000 ATX v3.1 Buy FSP Hydro Ti PRO 1000W Buy Montech Century II – 1050W Buy be quiet! Dark Power 13 1000W Buy NZXT C1000 Buy Montech Titan Gold 1000W Buy Thermaltake GF3 1000W Buy be quiet! Pure Power 13 M 1000W Buy MSI MPG A1000G PCIE 5 Buy Corsair RM1000x Shift Buy Corsair HX1000i Buy Seasonic PRIME TX-1000 Buy Corsair RM1000e

Article source: Hardware Busters

Original review link: https://hwbusters.com/psus/pccooler-yt1000-atx-v3-1-psu-review/

Weibo