Tech & Reviews

CPS PCCOOLER YT850 PSU Review: Specifications and Power Performance

Hardware Busters reviews the YT850 power supply, discussing hardware design, stated specifications and power-delivery performance. Read the original third-party article for the measurement setup, supporting results and any noted limitations.

CPS PCCOOLER YT850 ATX v3.1 PSU Review

The YT850 is Cybenetics Platinum-rated and tested against ATX 3.1 requirements. Its specified brief excursions up to 1700 W are not a 1700 W continuous output rating.

The CPS PCCOOLER YT850 is (or will be) included in my best ATX v3.x & PCIe 5.x PSU picks article.

The source identifies CPS PCCOOLER as the component brand of Shenzhen Fluence Technology, with products spanning coolers, fans, power supplies and lighting. It also notes the company's Chinese listing under stock code 300647 at the time of the article.

The CPS PCCOOLER YT line consists of three models with maximum power ratings of 850W, 1000W, and 1200W. All are certified by Cybenetics, and in today’s review, I will evaluate the weakest member of the line.

The source reports Cybenetics Platinum and ATX 3.1 results; no retail price was available at publication.

YT850 PSU Review: Specifications and Power Performance Check out our top ATX v3.1 PSU guide before purchasing your next PSU.

ATX v3.1 850W PSU Reviews:

Cybenetics PSU Test Database Best ATX v3.x PSUs

Power Specifications

Rail 3.3V 5V 12V 5VSB -12V
Max. Power Amps 20 20 70.8 3 0.3
Watts 110 849.6 15 3.6
Total Max. Power (W) 850

Box & Bundle

YT850 PSU Review: Specifications and Power Performance

I received early samples, so photos of the box are not available at this time. This means I can use any photo I want here. Here is one of my cats, Tom, relaxing after a hard day’s work!

Product Photos

psu_top_front

psu_top_front

psu_front

psu_front

psu_label

psu_label

psu_bottom

psu_bottom

psu_top_rear

psu_top_rear

psu_standby1

psu_standby1

psu_standby2

psu_standby2

psu_standby3

psu_standby3

Triangular openings shape the intake grille and rear exhaust. The AC side includes the inlet, main switch and a separate switch for enabling or disabling fan-stop operation. (YT850 PSU Review: Specifications and Power Performance)

The modular panel has eleven sockets, including a native 12V-2×6 header.

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (610mm) 1 1 18AWG No
4+4 pin EPS12V (650mm) 2 2 18AWG No
6+2 pin PCIe (600mm) 3 3 18AWG No
12+4 pin PCIe (650mm) (600W) 1 1 16-24AWG No
SATA (445mm+150mm+150mm) / 4-pin Molex (+150mm) 3 9 / 3 18AWG No
AC Power Cord (1380mm) – C13 coupler 1 1 18AWG –
box_cables

box_cables

cable2

cable2

cable3

cable3

cable4

cable4

cable5

cable5

cable6

cable6

cable1

cable1

The cables are long enough, and unlike the YT1200 model, the high-power cables (except 12V-2×6) use the standard AWG18 gauges instead of thicker (AWG16), which would offer lower voltage drops at high loads. The number of peripheral connectors is sufficient, and the distance between them is identical, at 150mm.

Part Analysis

General Data
Manufacturer (OEM) Andyson
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor SCK205R0 (5 ohm) & Relay
Bridge Rectifier(s) 2x GBU1006 (600V, 10A @ 100°C)
APFC MOSFETs 2x ChongQing PingWei PWE120N65SFMF (650V, 20A @ 100°C, Rds(on): 120mOhm)
APFC Boost Diode Global Power Technology G4S06508AT (650V, 8A @ 153°C)
Bulk Cap(s) 2x Nippon Chemi-Con (420V, 390uF each or 780uF combined, 2000h @ 105°C, KMW)
Main Switchers 4x Way-On WML26N65F2 (650V, 10.5A @ 100°C, Rds(on): 0.21Ohm)
APFC Controller Champion CM6500UNX
Resonant Controller Champion CU6901VPA
Topology Primary side: APFC, Full-Bridge & LLC Resonant Converter Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 8x Ping Wei PWC012N04ES (40V, 132A @ 100°C, Rds(on): 1.2mOhm)
5V & 3.3V DC-DC Converters: 6 x Way-On WMB050N03LG4 (30V, 41A @ 100°C, Rds(on): 5.4mOhm) PWM Controller(s): ANPEC APW7159C
Filtering Capacitors Electrolytic: 7x Rubycon (4-10,000h @105°C, YXS) 3x Rubycon (6-10,000h @105°C, ZLH) 2x Rubycon (4-10,000h @105°C, YXJ) Nippon Chemi-Con (10,000h @105°C, LE) Teapo (3,000h @105°C, SC) Polymer: 30x Polycap, 1x FPCAP
Supervisor IC Weltrend WT7518 (OVP, UVP, OCP, PG)
Fan Controller / Micro Controller Weltrend WT51F104
Fan Model Hong Hua HA13525H12F-Z (135mm, 12V, 0.50, Fluid Dynamic Bearing Fan)
5VSB Circuit
Rectifier (High Side) PJ335M
Standby PWM Controller Excelliance MOS EMB8569C
top1

top1

top2

top2

top3

top3

top4

top4

The Andyson platform uses a full-bridge LLC primary stage, eight +12 V switching devices and a pair of DC-to-DC converters for the minor outputs. The reviewer praises component selection but criticizes soldering on the supplied pre-production samples, also comparing a Sharkoon Rebel P20 on the same platform. Appearance alone does not establish whether joints are electrically or mechanically reliable.

Sharkoon Rebel P20 850 CPS PCCOOLER YT850
YT850 PSU Review: Specifications and Power Performance YT850 PSU Review: Specifications and Power Performance

Here is a comparison of the Sharkoon Rebel P20 PCB and the YT850 PCB. Unlike the YT1200 and YT1000, the YT850 has a green PCB instead of a black one. The soldering quality is also improved compared to the higher-capacity YT models, but this is not true for the PCB coating.

transienta1

transienta1

transienta2

transienta2

transientb1

transientb1

transientb2

transientb2

The EMI filter runs from the AC inlet onto the main PCB and includes the components shown in the internal photographs. Its actual effectiveness is evaluated by the later emissions tests.

MOV

MOV

NTC_&_relay

NTC_&_relay

The input stage has a surge MOV and a 5 Ω NTC thermistor, supported by a bypass relay.

bridge_rectifiers1

bridge_rectifiers1

bridge_rectifiers2

bridge_rectifiers2

The two GBU1006 parallel bridge rectifiers can handle up to 50A together.

APFC_FETs1

APFC_FETs1

APFC_FETs2

APFC_FETs2

boost_diode

boost_diode

bulk_caps

bulk_caps

The APFC converter utilizes two Chongqing Pingwei PWE120N65SFMF FETs and one Global Power Technology G4S06508AT boost diode. Nippon Chemi-Con manufactures the bulk capacitors. Their combined capacity is 780 μF, and both are rated for 2,000 hours at 105 °C. The voltage rating is 420V, which is higher than the APFC’s DC bus voltage (approximately 380-400V DC).

YT850 PSU Review: Specifications and Power Performance

The APFC controller is Champion CM6500UNX.

YT850 PSU Review: Specifications and Power Performance

Four Way-On WML26N65F2 primary switching FETs are installed in a full-bridge topology, and an LLC resonant converter is utilized for enhanced efficiency.

YT850 PSU Review: Specifications and Power Performance

The LLC resonant controller is Champion CU6901VPA.

YT850 PSU Review: Specifications and Power Performance

The main transformer provides electrical isolation between the primary and secondary circuits as part of power conversion.

YT850 PSU Review: Specifications and Power Performance

Eight Ping Wei PWC012N04ES FETs regulate the 12V rail.

minor_rail_FETs

minor_rail_FETs

PWM_controller

PWM_controller

Two DC-DC converters generate the minor rails. They use six Way-On WMB050N03LG4 FETs. The PWM controller is an Anpec APW7159C .

caps1

caps1

caps2

caps2

caps3

caps3

caps4

caps4

Electrolytic capacitors are from Chemi-Con, Rubycon and Teapo; polymer capacitors are from FPCAP and Polycap.

You can find more information about capacitor performance and other specs below:

standby_PWM_controller

standby_PWM_controller

5vsb_transformer

5vsb_transformer

The standby PWM controller is Excelliance MOS EMB8569C.

modular_board1

modular_board1

modular_board2

modular_board2

modular_board3

modular_board3

Polymer capacitors on the modular panel add another output-filtering stage.

main_PCB1

main_PCB1

main_PCB2

main_PCB2

main_PCB3

main_PCB3

The soldering quality is decent, but the PCB coating is poor.

fan

fan

fan_close

fan_close

The cooling fan is a Hong Hua HA13525H12F-Z, utilizing a fluid dynamic bearing.

Load Regulation

Load regulation measures how output voltage changes as the connected load varies.

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 5.226A 1.964A 1.94A 0.989A 85.008 85.082% 0 <6.0 48.75°C 0.968
12.132V 5.093V 3.403V 5.057V 99.913 40.01°C 114.91V
20% 11.466A 2.947A 2.911A 1.19A 169.982 90.411% 0 <6.0 49.9°C 0.981
12.129V 5.092V 3.401V 5.043V 188.008 40.57°C 114.89V
30% 18.085A 3.438A 3.397A 1.392A 254.997 91.901% 0 <6.0 50.78°C 0.986
12.105V 5.092V 3.4V 5.03V 277.467 41.05°C 114.87V
40% 24.695A 3.929A 3.883A 1.595A 340.095 92.076% 0 <6.0 56.23°C 0.986
12.102V 5.092V 3.4V 5.017V 369.361 41.85°C 114.84V
50% 30.957A 4.911A 4.855A 1.799A 425.122 91.822% 0 <6.0 57.21°C 0.987
12.101V 5.092V 3.399V 5.003V 462.982 42.23°C 114.82V
60% 37.188A 5.9A 5.833A 2.001A 509.644 91.282% 873 25.7 42.68°C 0.986
12.097V 5.087V 3.395V 4.989V 558.318 64.8°C 114.8V
70% 43.491A 6.889A 6.812A 2.212A 594.993 90.826% 872 25.7 43.09°C 0.986
12.092V 5.083V 3.392V 4.975V 655.087 65.59°C 114.78V
80% 49.791A 7.874A 7.788A 2.317A 679.82 90.331% 868 25.6 43.6°C 0.987
12.089V 5.08V 3.39V 4.965V 752.593 68.33°C 114.75V
90% 56.479A 8.368A 8.262A 2.423A 765.253 89.733% 863 25.4 44.04°C 0.988
12.088V 5.08V 3.389V 4.954V 852.809 72.35°C 114.72V
100% 62.915A 8.861A 8.767A 3.045A 850.036 88.965% 1448 40.2 45.82°C 0.989
12.085V 5.079V 3.388V 4.927V 955.473 70.23°C 114.7V
110% 69.223A 9.852A 9.84A 3.05A 934.628 88.33% 1450 40.2 46.58°C 0.989
12.082V 5.076V 3.384V 4.919V 1058.114 72.14°C 114.66V
CL1 0.116A 13.02A 12.857A 0A 111.312 82.778% 874 25.7 41.43°C 0.977
12.145V 5.085V 3.399V 5.078V 134.473 58.68°C 114.9V
CL2 0.115A 19.707A 0A 0A 101.403 80.714% 1453 40.3 40.03°C 0.974
12.139V 5.074V 3.405V 5.084V 125.631 50.91°C 114.9V
CL3 0.115A 0A 19.455A 0A 67.396 74.435% 1452 40.3 39.76°C 0.963
12.133V 5.096V 3.392V 5.082V 90.542 47.9°C 114.91V
CL4 70.354A 0A 0A 0.001A 849.882 89.586% 1445 40.1 45.21°C 0.988
12.080V 5.088V 3.393V 5.041V 948.676 65.25°C 114.69V
regulation_12v_115V

regulation_12v_115V

regulation_12v_230V

regulation_12v_230V

regulation_5v_115V

regulation_5v_115V

regulation_5v_230V

regulation_5v_230V

regulation_33v_115V

regulation_33v_115V

regulation_33v_230V

regulation_33v_230V

regulation_5vsb_115V

regulation_5vsb_115V

regulation_5vsb_230V

regulation_5vsb_230V

Load regulation is within 1% on all primary rails, so all is good here.

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
20W 1.234A 0.491A 0.485A 0.196A 20.009 75.594% 0 <6.0 43.52°C 0.782
12.037V 5.091V 3.402V 5.089V 26.47 36.6°C 114.94V
40W 2.716A 0.688A 0.679A 0.295A 40.006 82.505% 0 <6.0 46.11°C 0.909
12.040V 5.091V 3.402V 5.085V 48.488 37.27°C 114.93V
60W 4.166A 0.884A 0.873A 0.394A 60.005 81.929% 0 <6.0 47.01°C 0.951
12.129V 5.092V 3.403V 5.08V 73.242 38.46°C 114.92V
80W 5.634A 1.08A 1.067A 0.493A 79.975 85.121% 0 <6.0 48.07°C 0.965
12.131V 5.094V 3.404V 5.075V 93.954 39.27°C 114.92V

A glance at the light-load table is always useful, as the PSU typically operates at light loads.

Ripple Suppression

Ripple is the unwanted AC component superimposed on a DC output. The test measures its amplitude to assess filtering quality and compares the result with the stated limits. Lower ripple is preferable, but this measurement alone does not establish component lifetime.

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 14.3 mV 14.6 mV 10.5 mV 19.9 mV Pass
20% Load 16.2 mV 15.3 mV 11.7 mV 20.9 mV Pass
30% Load 17.3 mV 16.8 mV 13.1 mV 22.3 mV Pass
40% Load 17.0 mV 19.9 mV 16.1 mV 22.6 mV Pass
50% Load 16.8 mV 18.4 mV 13.9 mV 23.6 mV Pass
60% Load 13.0 mV 10.3 mV 8.9 mV 16.3 mV Pass
70% Load 13.3 mV 11.4 mV 9.4 mV 17.0 mV Pass
80% Load 13.3 mV 11.5 mV 13.4 mV 19.4 mV Pass
90% Load 13.8 mV 11.1 mV 14.6 mV 18.9 mV Pass
100% Load 15.8 mV 13.6 mV 15.8 mV 21.4 mV Pass
110% Load 18.2 mV 13.4 mV 16.8 mV 21.0 mV Pass
Crossload 1 12.1 mV 10.1 mV 11.9 mV 12.8 mV Pass
Crossload 2 11.3 mV 8.9 mV 6.3 mV 10.3 mV Pass
Crossload 3 9.3 mV 8.8 mV 13.4 mV 10.7 mV Pass
Crossload 4 16.8 mV 11.7 mV 11.6 mV 15.8 mV Pass
ripple_12v_115V

ripple_12v_115V

ripple_12v_230V

ripple_12v_230V

ripple_5v_115V

ripple_5v_115V

ripple_5v_230V

ripple_5v_230V

ripple_33v_115V

ripple_33v_115V

ripple_33v_230V

ripple_33v_230V

ripple_5vsb_115V

ripple_5vsb_115V

ripple_5vsb_230V

ripple_5vsb_230V

Ripple suppression is good overall.

Transient Response

Transient response describes voltage deviation and recovery when load changes suddenly. Both the size of the excursion and recovery time matter when comparing the same test pattern.

20% Load – 20ms

Advanced Transient Response 20% - 50 Hz - No Caps
Voltage Before After Change Pass/Fail
12V 12.119V 11.927V 1.59% Pass
5V 5.081V 4.958V 2.41% Pass
3.3V 3.392V 3.219V 5.11% Pass
5VSB 5.044V 4.991V 1.05% Pass

50% Load -20ms

Advanced Transient Response 50% - 50 Hz - No Caps
Voltage Before After Change Pass/Fail
12V 12.083V 11.962V 1.00% Pass
5V 5.076V 4.947V 2.55% Pass
3.3V 3.386V 3.207V 5.28% Pass
5VSB 5.005V 4.931V 1.47% Pass
transient_12v_115V

transient_12v_115V

transient_5v_115V

transient_5v_115V

transient_33v_115V

transient_33v_115V

transient_5vsb_115V

transient_5vsb_115V

The transient response is mediocre overall.

Transient Response ATX v3.1 Tests

[Note] For PSUs without a 12+4 pin connector, the maximum applied load for the transient response tests is 150%, rather than 200%.

transient_120_dev

transient_120_dev

transient_120_voltage

transient_120_voltage

transient_160_dev

transient_160_dev

transient_160_voltage

transient_160_voltage

transient_180_dev

transient_180_dev

transient_180_voltage

transient_180_voltage

transient_200_dev

transient_200_dev

transient_200_voltage

transient_200_voltage

The PSU passes all ATX v3.1 transient response tests.

transient_120_dev

transient_120_dev

transient_120_voltage

transient_120_voltage

transient_160_dev

transient_160_dev

transient_160_voltage

transient_160_voltage

transient_180_dev

transient_180_dev

transient_180_voltage

transient_180_voltage

transient_200_dev

transient_200_dev

transient_200_voltage

transient_200_voltage

The 12V rail’s performance is above average in these tests.

Hold Up Time

Hold-up time is the interval for which output remains within its specified range after AC input is interrupted. It is measured in milliseconds and helps bridge very brief interruptions; it is not a substitute for a UPS or a guarantee of enough time for an operating-system shutdown.

hold_up_time

hold_up_time

ac_loss_hold_up_time

ac_loss_hold_up_time

pwr_ok_inactive_to_dc_loss_delay

pwr_ok_inactive_to_dc_loss_delay

The hold-up time is extended.

Inrush Current

YT850 PSU Review: Specifications and Power Performance YT850 PSU Review: Specifications and Power Performance

We recently changed the methodology for conducting inrush current measurements and the required equipment, so I had to re-run the corresponding tests and update all relevant PSU review charts. This is still a work in progress.

Leakage Current

Leakage current is current flowing through paths other than the intended functional circuit. In PSU testing, the measurement arrangement and the distinction between protective-conductor and touch current must be considered.

In an earthed PSU, EMI-filter Y capacitors contribute AC current to the protective conductor. The measured current depends on capacitance, input voltage, frequency and the test circuit, not simply on the number of capacitors.

The source cites IEC 62368-1 for its leakage and touch-current assessment. Compliance depends on the applicable equipment category and test conditions.

  • Normal Condition: Maximum touch current = 3.5 mA
  • Single Fault Condition: Maximum touch current = 10 mA

YT850 PSU Review: Specifications and Power Performance

The leakage current is low.

PSU Timings

PSU timing tests check the sequence and duration of startup, power-good and shutdown signals against the stated ATX criteria. These should be read as measured timing behavior, not an independent guarantee against every system fault.

Alternative Low Power Modes concern low-power system operation and transitions between power states. The review examines their associated ATX timing requirements, including T1 and T3.

T1 and T3 Timings Explained

YT850 PSU Review: Specifications and Power Performance

  • T1 (power-on time) measures the interval from PS_ON# assertion until the main outputs enter regulation. The subsequent PWR_OK delay is T3 and must be assessed separately. Apply the limits for the relevant ATX revision and low-power-mode requirements.
  • T3 (PWR_OK delay) is the interval from the outputs entering regulation until PWR_OK is asserted. It is distinct from T1. Compare results using the criteria for the same ATX revision and operating mode.
timing_20%_t1

timing_20%_t1

timing_20%_t3

timing_20%_t3

timing_100%_t1

timing_100%_t1

timing_100%_t3

timing_100%_t3

The PSU supports Alternative Low Power Modes.

Efficiency Normal, Light & Super-Light Loads

Efficiency is DC output power divided by AC input power. For example, delivering 400 W at 80% efficiency requires 500 W input, leaving 100 W as conversion loss.

avg_efficiency_normal_loads1_115V

avg_efficiency_normal_loads1_115V

avg_efficiency_normal_loads1_230V

avg_efficiency_normal_loads1_230V

avg_efficiency_low_loads1_115V

avg_efficiency_low_loads1_115V

avg_efficiency_low_loads1_230V

avg_efficiency_low_loads1_230V

efficiency_ultra_low_load1_115

efficiency_ultra_low_load1_115

efficiency_ultra_low_load1_230

efficiency_ultra_low_load1_230

High enough average efficiency on all load ranges.

Average Efficiency

The PSU’s average efficiency with more than 1450 different load levels at 115V and 230V is depicted in the graphs below.

avg_eff_115V

avg_eff_115V

avg_eff_230V

avg_eff_230V

The average efficiency meets the Cybenetics Platinum criteria.

Average PF

Power factor is real power in watts divided by apparent power in volt-amperes. It describes AC input-current behavior and is distinct from conversion efficiency. Active PFC aims to bring it closer to unity.

avg_pf_115V

avg_pf_115V

avg_pf_230V

avg_pf_230V

The APFC converter needs tuning for higher PF readings.

Average Efficiency 5VSB

5VSB_efficiency_115V

5VSB_efficiency_115V

5VSB_efficiency_230V

5VSB_efficiency_230V

The 5VSB rail’s efficiency is satisfactory at 115V, but I would like to see close to 80% also at 230V input.

Vampire Power

Standby input power is drawn while the PSU is connected to AC but not supplying the main system outputs. Functions such as +5VSB remain available. The measurement depends on the standby load and operating state.

Stand_By_115V

Stand_By_115V

Stand_By_230V

Stand_By_230V

Vampire power is below 0.1W at 115V, but notably above this threshold at 230V.

Protection Features

PSU protection tests examine responses to overload and other specified abnormal conditions. The presence of protection circuitry should be distinguished from its measured triggering thresholds and behavior.

OCP (Normal @ 27.6°C) 12V: 100.20A (141.53%), 12.104V 5V: 30A (150.00%), 5.057V 3.3V: 29A (145.00%), 3.385V 5VSB: 6.5A (216.67%), 4.878V
OCP (Hot @ 44.0°C) 12V: 99.40A (140.40%), 12.104V 5V: 30A (150.00%), 5.061V 3.3V: 29A (145.00%), 3.391V 5VSB: 6.4A (213.33%), 4.878V
OPP (Normal @ 28.1°C) 1261.07W (148.36%)
OPP (Hot @ 42.8°C) 1103.97W (129.88%)
OTP ✓ (144°C @ Heat Sink)
SCP 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK Proper Operation
UVP (Full Load @ 90V) ✓
UVP (No Damage @ 80V) ✓
Conducted Emissions EN55032 & CISPR 32 ✓
NLO ✓
Fan Failure Protection ✗
SIP Surge: MOV Inrush: NTC & Bypass Relay

As in the 1000W model, the OCP triggering points are not correctly set to 12V. The difference between the normal and hot triggering points is too close, not effectively protecting the unit under high operating temperatures. Also, similar to the YT1200 and YT1000, the minor rails have high OCP triggering points compared to the nominal ratings, and to make matters worse, there is no difference in the triggering points between normal and high temperatures.

The reviewer considers OPP thresholds appropriately separated between normal and hot conditions. The other listed protections worked in the tests, but fan-failure protection was not implemented in the sample.

EMC Pre-Compliance at a Glance

The source evaluates electromagnetic emissions using CISPR 32/EN 55032 reference limits, including the stricter Class B limits associated with domestic equipment. These pre-compliance measurements do not by themselves establish complete regulatory certification.

Our equipment for EMI readings:

  • Rohde & Schwarz FPC1500 (loaded with all options)
  • Tekbox TBLC08 LISN
  • Tekbox TBFL1 transient limiter
  • Tekbox EMCview software
CISPR 32 / EN55032 Limits
CISPR 32 / EN 55032 Class A Conducted EMI Limit
Frequency of Emission (MHz) Conducted Limit (dBuV)
Quasi-peak Average
0.15 – 0.50 79 66
0.50 – 30.0 73 60
CISPR 32 / EN 55032 Class B Conducted EMI Limit
Frequency of Emission (MHz) Conducted Limit (dBuV)
Quasi-peak Average
0.15 – 0.50 66 – 56 56 – 46
0.50 – 5.00 56 46
5.00 – 30.00 60 50

The review applies the 4 dB margin described in its ATX emissions criteria. Passing that comparison should not be confused with independently demonstrating compliance with every applicable EMC limit.

EMI Results

YT850 PSU Review: Specifications and Power Performance

EMI pre-compliance results were controlled, unlike those of the tested YT1200.

Average Noise

avg_noise_115V

avg_noise_115V

avg_noise_230V

avg_noise_230V

The PSU’s average noise output is low.

Fan Noise & Speed Maps @ 28-32 °C – 115V

CL_Fan_Noise

CL_Fan_Noise

CL_Fan_Speed

CL_Fan_Speed

The fan speed profile is not aggressively set. The fan’s passive mode lasts up to 395W at 12V, with the load on the minor rails remaining below 70W. At loads up to 395W, if you apply more than 70W to the minor rails, the fan’s speed increases, raising the noise level to 10-15 dBA, which is not particularly high. For loads above 395W, the fan’s noise exceeds 20 dBA when more than 70-75W is applied to the minor rails. The 30 dBA mark is reached at around 705W, and if you push the minor rails with loads above 95W (while keeping over 705W at 12V), noise exceeds 40 dBA.

Fan Noise & Speed Maps @ 28-32 °C – 230V

CL_Fan_Noise

CL_Fan_Noise

CL_Fan_Speed

CL_Fan_Speed

At 230V, the fan speed profile is almost similar to the 115V input one. Strangely enough, the fan’s passive operation period shrinks a bit, but the same goes for the 20-25 dBA operating range.

Overall Performance

Here is the link to read more about this performance algorithm.

perf_115V

perf_115V

perf_230V

perf_230V

The overall performance is competitive at 115V, but at 230V, the PSU’s performance is affected (or the competition performs better at this input).

Epilogue

The YT850 sample showed improved soldering over the supplied higher-capacity units, competitive efficiency, regulation, ripple and inrush behavior, and long hold-up time. Its normal +12 V transient response was weaker, despite passing the separate ATX excursion tests. EMI filtering was effective, while APFC power factor at 230 V and OCP thresholds remained concerns. OPP was considered correctly set.

The relaxed fan profile lowers average noise, though heavy minor-rail demand can raise noise, particularly when +12 V also exceeds roughly 700 W. The relevant consideration is the combined load distribution, including any substantial +5 V lighting demand.

All in all, the CPS PCCOOLER YT850 offers competitive overall performance. The only reason I don’t provide a recommendation award is that I decided some time ago not to do so if the protection features (OCP mostly) are not correctly set. Additionally, since I don’t have any pricing information (at the time of the review), I cannot comment on its price-per-performance ratio.

YT850 PSU Review: Specifications and Power Performance

The original reviewer links to a comparison of ATX v3.x power supplies and discloses that purchases through affiliate links may earn a commission without changing the listed price. (Reference 1)

Buy CPS PCCOOLER YT850 ATX v3.1 Buy be quiet! Pure Power 13 M 850W Buy FSP VITA GM Buy XPG Core Reactor II 850W Buy Thermaltake Toughpower GF A3 850W Buy Enermax Revolution D.F. 2 850W Buy Cooler Master MWE Gold 850 V2 Buy Segotep GM850 Buy Corsair RM850e Buy SilverStone HELA 850R   Buy MSI MAG A850GL PCIE 5 Buy SilverStone Extreme 850R Platinum Buy Segotep GM850 Buy Seasonic Vertex GX-850 Buy be quiet! Pure Power 12 M 850W Buy Corsair RM850x Shift Buy be quiet! Dark Power 13 850W Buy Cooler Master Elite Gold 850 Buy Montech Titan Gold 850W

Article source: Hardware Busters

Original review link: https://hwbusters.com/psus/pccooler-yt850-atx-v3-1-psu-review/

Weibo