Tech & Reviews

CPS PCCOOLER YT1200 PSU Review: Specifications and Power Performance

Hardware Busters reviews the YT1200 power supply, discussing hardware design, stated specifications and power-delivery performance. Read the original third-party article for the measurement setup, supporting results and any noted limitations.

CPS PCCOOLER YT1200 ATX v3.1 PSU Review

The YT1200 is a Cybenetics Platinum-rated PSU tested for ATX 3.1 compliance. Its support for specified brief power excursions should not be confused with a 2400 W continuous rating. This review covers the tested pre-production sample.

The CPS PCCOOLER YT1200 is (or will be) included in my best ATX v3.x & PCIe 5.x PSU picks article.

The source identifies CPS PCCOOLER as the component brand of Shenzhen Fluence Technology, with products spanning coolers, fans, power supplies and lighting. It also notes the company's Chinese listing under stock code 300647 at the time of the article.

The CPS PCCOOLER YT line consists of three models with maximum power ratings of 850W, 1000W, and 1200W. All are certified by Cybenetics, and in today’s review, I will evaluate the strongest member of the line.

At publication, the source reported Cybenetics Platinum and ATX 3.1 results but had no retail price to assess.

YT1200 PSU Review: Specifications and Power Performance Check out our top ATX v3.1 PSU guide before purchasing your next PSU.

High-Capacity ATX v3.1 PSU Reviews:

Cybenetics PSU Test Database Best ATX v3.x PSUs

Power Specifications

Rail 3.3V 5V 12V 5VSB -12V
Max. Power Amps 20 20 100 3 0.3
Watts 100 1200 15 3.6
Total Max. Power (W) 1200

Box & Bundle

YT1200 PSU Review: Specifications and Power Performance

I received early samples, so photos of the box are not available at this time. This means I can use any photo I want here, such as a photo of my plane, the Cessna C182. Old but reliable and really nice to fly!

Product Photos

psu_top_front

psu_top_front

psu_front

psu_front

psu_side

psu_side

psu_bottom

psu_bottom

psu_label

psu_label

psu_top_rear

psu_top_rear

psu_standby1

psu_standby1

psu_standby2

psu_standby2

psu_standby3

psu_standby3

Triangular openings shape the intake grille and rear exhaust. The AC side includes the inlet, main switch and a separate switch for enabling or disabling fan-stop operation. (YT1200 PSU Review: Specifications and Power Performance)

The modular panel has eleven sockets, including a native 12V-2×6 header.

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (610mm) 1 1 16AWG No
4+4 pin EPS12V (650mm) 2 2 16AWG No
6+2 pin PCIe (600mm) 3 3 16AWG No
12+4 pin PCIe (650mm) (600W) 1 1 16-24AWG No
SATA (445mm+150mm+150mm) / 4-pin Molex (+150mm) 3 9 / 3 18AWG No
AC Power Cord (1380mm) – C13 coupler 1 1 18AWG –
box_cables

box_cables

cable2

cable2

cable3

cable3

cable4

cable4

cable5

cable5

cable6

cable6

cable1

cable1

The cables are long enough, and the high-power cables use thicker, 16AWG, for lower voltage drops at high loads. The number of peripheral connectors is sufficient, and the distance between them is identical, at 150mm.

Part Analysis

General Data
Manufacturer (OEM) Andyson
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor SCK205R0 (5 ohm) & Relay
Bridge Rectifier(s) 2x MCC Semi GBU2508 (800V, 25A @ 98°C)
APFC MOSFETs 2x Way-on WML53N60C4 (600V, 26A @ 100°C, Rds(on): 0.07Ohm)
APFC Boost Diode CREE C3D10060A (600V, 10A @ 150°C)
Bulk Cap(s) 2x Nippon Chemi-Con (450V, 560uF each or 1120uF combined, 2000h @ 105°C, KMW)
Main Switchers 4x Way-On WML36N60F2 (600V, 20A @ 100°C, Rds(on): 0.11Ohm)
APFC  Controller Champion CM6500UNX
Resonant Controller Champion CU6901VPA
Topology Primary side: APFC, Full-Bridge & LLC Resonant converter Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 8x Ping Wei PWC012N4ES (40V, 132A @ 100°C, Rds(on): 1.2mOhm)
5V & 3.3V DC-DC Converters: 6 x Way-On WMB050N03LG4 (30V, 41A @ 100°C, Rds(on): 5.4mOhm) PWM Controller(s): ANPEC APW7159C
Filtering Capacitors Electrolytic: 7x Rubycon (4-10,000h @105°C, YXS) 4x Rubycon (6-10,000h @105°C, ZLH) 1x Rubycon (4-10,000h @105°C, YXJ) Nippon Chemi-Con (10,000h @105°C, LE) Teapo (3,000h @105°C, SC) Polymer: 15x FPCAP, 15x Polycap, 1x no info
Supervisor IC Weltrend WT7527 (OCP, OTP, OVP, UVP, SCP, PG)
Fan Controller / Micro Controller Weltrend WT51F104
Fan Model Hong Hua HA13525H12F-Z (135mm, 12V, 0.50, Fluid Dynamic Bearing Fan)
5VSB
Rectifier PJ335M
Standby PWM Controller Excelliance MOS EMB8569C
top1

top1

top2

top2

top3

top3

top4

top4

The Andyson platform uses a full-bridge LLC primary stage, eight +12 V switching devices and a pair of DC-to-DC converters for the minor outputs. The reviewer praises component selection but criticizes soldering on the supplied pre-production samples, also comparing a Sharkoon Rebel P20 on the same platform. Appearance alone does not establish whether joints are electrically or mechanically reliable.

Sharkoon Rebel P20 1200 CPS PCCOOLER YT1200
YT1200 PSU Review: Specifications and Power Performance YT1200 PSU Review: Specifications and Power Performance

Here is a comparison between the Sharkoon Rebel’s P20 PCB and the YT1200’s PCB. As you can see, besides the different PCB colors, there are differences in the soldering and coating quality. Because some of the YT1200’s parts are not recognizable, I will use some photos of the Rebel P20 where the marking can be distinguished.

transienta1

transienta1

transienta2

transienta2

transientb1

transientb1

transientb2

transientb2

The EMI filter runs from the AC inlet onto the main PCB and includes the components shown in the internal photographs. Its actual effectiveness is evaluated by the later emissions tests.

MOV

MOV

NTC_&_relay

NTC_&_relay

The input stage has a surge MOV and a 5 Ω NTC thermistor, supported by a bypass relay.

bridge_rectifiers1

bridge_rectifiers1

bridge_rectifiers2

bridge_rectifiers2

The two GBU2508 parallel bridge rectifiers can handle up to 50A together.

APFC_FETs_&_boost_diode

APFC_FETs_&_boost_diode

bulk_caps

bulk_caps

The APFC converter uses two Way-on WML53N60C4 FETs and one CREE C3D10060A boost diode. Nippon Chemi-Con manufactures the bulk capacitors. Their combined capacity is 1120 μF, and both are rated for 2,000 hours at 105 °C. The voltage rating is 450V, which is significantly higher than the APFC’s DC bus voltage (approximately 380-400V DC).

YT1200 PSU Review: Specifications and Power Performance

The APFC controller is Champion CM6500UNX.

YT1200 PSU Review: Specifications and Power Performance

Four Way-On WML36N60F2 primary switching FETs are installed in a full-bridge topology, and an LLC resonant converter is utilized for enhanced efficiency.

YT1200 PSU Review: Specifications and Power Performance

The LLC resonant controller is Champion CU6901VPA.

YT1200 PSU Review: Specifications and Power Performance

The main transformer provides electrical isolation between the primary and secondary circuits as part of power conversion.

YT1200 PSU Review: Specifications and Power Performance

Eight Ping Wei PWC012N4ES FETs regulate the 12V rail.

minor_rail_FETs

minor_rail_FETs

PWM_controller

PWM_controller

Two DC-DC converters generate the minor rails. They use six Way-On WMB050N03LG4 FETs. The PWM controller is an Anpec APW7159C .

caps1

caps1

caps2

caps2

caps3

caps3

caps4

caps4

Electrolytic capacitors are from Chemi-Con, Rubycon and Teapo; polymer capacitors are from FPCAP and Polycap.

You can find more information about capacitor performance and other specs below:

standby_PWM_controller

standby_PWM_controller

5vsb_transformer

5vsb_transformer

The standby PWM controller is Excelliance MOS EMB8569C.

modular_board1

modular_board1

modular_board2

modular_board2

modular_board3

modular_board3

Polymer capacitors on the modular panel add another output-filtering stage.

main_PCB1

main_PCB1

main_PCB2

main_PCB2

main_PCB3

main_PCB3

The soldering quality is terrible!

fan

fan

fan_close

fan_close

The cooling fan is a Hong Hua HA13525H12F-Z, utilizing a fluid dynamic bearing.

Load Regulation

Load regulation measures how output voltage changes as the connected load varies.

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
10% 8.119A 1.991A 1.952A 0.983A 120.015 86.011% 0 <6.0 47.26°C 0.974
12.122V 5.024V 3.381V 5.09V 139.542 40.44°C 114.93V
20% 17.252A 2.988A 2.931A 1.182A 239.981 90.881% 0 <6.0 47.68°C 0.976
12.119V 5.021V 3.378V 5.078V 264.055 40.72°C 114.9V
30% 26.723A 3.488A 3.422A 1.382A 359.396 91.865% 0 <6.0 48.71°C 0.977
12.100V 5.019V 3.375V 5.065V 391.225 41.42°C 114.87V
40% 36.251A 3.988A 3.914A 1.584A 479.758 91.714% 908 26.8 41.84°C 0.981
12.097V 5.017V 3.373V 5.053V 523.104 58.94°C 114.83V
50% 45.392A 4.987A 4.897A 1.786A 599.522 91.424% 907 26.7 42.36°C 0.984
12.095V 5.014V 3.369V 5.041V 655.758 59.25°C 114.79V
60% 54.586A 5.988A 5.882A 1.989A 720.047 90.885% 903 26.5 42.95°C 0.986
12.096V 5.011V 3.367V 5.028V 792.265 62.35°C 114.76V
70% 63.720A 6.991A 6.869A 2.193A 839.783 90.157% 1484 41.2 43.03°C 0.987
12.095V 5.008V 3.363V 5.016V 931.463 57.19°C 114.73V
80% 72.917A 7.994A 7.856A 2.298A 959.785 89.458% 1482 41.1 43.85°C 0.988
12.095V 5.004V 3.36V 5.006V 1072.886 60.19°C 114.7V
90% 82.410A 8.498A 8.339A 2.403A 1079.599 88.631% 1478 40.9 44.82°C 0.989
12.099V 5.002V 3.358V 4.995V 1218.079 64.16°C 114.66V
100% 91.726A 9.001A 8.853A 3.017A 1199.669 87.681% 1866 48.4 45.33°C 0.99
12.100V 5V 3.355V 4.972V 1368.213 63.41°C 114.62V
110% 100.949A 10.005A 9.935A 3.023A 1320.287 86.609% 1860 48.4 46.63°C 0.991
12.105V 4.998V 3.352V 4.963V 1524.423 67.97°C 114.58V
CL1 0.116A 12.015A 11.765A 0A 101.303 82.663% 919 27.4 40.07°C 0.976
12.064V 5.011V 3.374V 5.106V 122.555 54.91°C 114.95V
CL2 0.115A 19.985A 0A 0A 101.398 78.933% 1194 35.5 40.89°C 0.974
12.131V 5.004V 3.383V 5.111V 128.457 48.9°C 114.95V
CL3 0.116A 0A 19.583A 0A 67.39 76.424% 1199 35.6 40.07°C 0.958
12.050V 5.025V 3.37V 5.11V 88.179 46.13°C 114.96V
CL4 99.293A 0A 0A 0.001A 1200.099 88.312% 1867 48.4 45.94°C 0.99
12.086V 5.014V 3.364V 5.059V 1358.939 60.66°C 114.63V
regulation_12v_115V

regulation_12v_115V

regulation_12v_230V

regulation_12v_230V

regulation_5v_115V

regulation_5v_115V

regulation_5v_230V

regulation_5v_230V

regulation_33v_115V

regulation_33v_115V

regulation_33v_230V

regulation_33v_230V

regulation_5vsb_115V

regulation_5vsb_115V

regulation_5vsb_230V

regulation_5vsb_230V

Load regulation is within 1% on all primary rails, so all is good here.

Test 12V 5V 3.3V 5VSB DC/AC (Watts) Efficiency Fan Speed (RPM) PSU Noise (dB[A]) Temps (In/Out) PF/AC Volts
20W 1.234A 0.497A 0.487A 0.195A 20.005 71.534% 0 <6.0 44.36°C 0.727
12.041V 5.028V 3.385V 5.119V 26.208 36.39°C 114.96V
40W 2.715A 0.696A 0.682A 0.293A 40.002 82.267% 0 <6.0 44.72°C 0.89
12.041V 5.028V 3.385V 5.115V 48.623 37.25°C 114.96V
60W 4.194A 0.895A 0.878A 0.391A 60.001 85.163% 0 <6.0 44.25°C 0.942
12.047V 5.027V 3.384V 5.11V 70.459 38.23°C 114.94V
80W 5.670A 1.095A 1.073A 0.49A 79.963 86.388% 0 <6.0 43.85°C 0.96
12.050V 5.026V 3.383V 5.106V 92.566 39.03°C 114.94V

A glance at the light loads table is always useful, as the PSU will typically operate at light loads.

Ripple Suppression

Ripple is the unwanted AC component superimposed on a DC output. The test measures its amplitude to assess filtering quality and compares the result with the stated limits. Lower ripple is preferable, but this measurement alone does not establish component lifetime.

Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 13.1 mV 7.4 mV 6.1 mV 12.9 mV Pass
20% Load 11.6 mV 8.2 mV 6.8 mV 14.2 mV Pass
30% Load 11.8 mV 8.9 mV 7.2 mV 16.1 mV Pass
40% Load 12.2 mV 13.5 mV 11.9 mV 15.7 mV Pass
50% Load 13.4 mV 9.8 mV 8.9 mV 18.0 mV Pass
60% Load 13.2 mV 10.1 mV 9.5 mV 17.3 mV Pass
70% Load 13.1 mV 10.6 mV 10.2 mV 20.9 mV Pass
80% Load 13.3 mV 11.9 mV 16.0 mV 20.8 mV Pass
90% Load 14.3 mV 11.7 mV 16.9 mV 21.2 mV Pass
100% Load 18.2 mV 12.0 mV 18.1 mV 27.7 mV Pass
110% Load 17.3 mV 12.5 mV 19.0 mV 28.8 mV Pass
Crossload 1 20.1 mV 10.6 mV 13.5 mV 10.9 mV Pass
Crossload 2 12.6 mV 9.6 mV 6.7 mV 9.2 mV Pass
Crossload 3 21.7 mV 8.7 mV 15.0 mV 9.7 mV Pass
Crossload 4 17.1 mV 11.6 mV 12.1 mV 16.1 mV Pass
ripple_12v_115V

ripple_12v_115V

ripple_12v_230V

ripple_12v_230V

ripple_5v_115V

ripple_5v_115V

ripple_5v_230V

ripple_5v_230V

ripple_33v_115V

ripple_33v_115V

ripple_33v_230V

ripple_33v_230V

ripple_5vsb_115V

ripple_5vsb_115V

ripple_5vsb_230V

ripple_5vsb_230V

Ripple suppression is good overall.

Transient Response

Transient response describes voltage deviation and recovery when load changes suddenly. Both the size of the excursion and recovery time matter when comparing the same test pattern.

20% Load – 20ms

Advanced Transient Response 20% - 50 Hz - No Caps
Voltage Before After Change Pass/Fail
12V 12.109V 11.940V 1.39% Pass
5V 5.021V 4.914V 2.12% Pass
3.3V 3.377V 3.186V 5.64% Pass
5VSB 5.082V 5.035V 0.93% Pass

50% Load -20ms

Advanced Transient Response 50% - 50 Hz - No Caps
Voltage Before After Change Pass/Fail
12V 12.078V 11.973V 0.87% Pass
5V 5.014V 4.913V 2.02% Pass
3.3V 3.368V 3.170V 5.89% Pass
5VSB 5.047V 5.001V 0.92% Pass
transient_12v_115V

transient_12v_115V

transient_5v_115V

transient_5v_115V

transient_33v_115V

transient_33v_115V

transient_5vsb_115V

transient_5vsb_115V

The transient response is average at 12V, and mediocre on the minor rails.

Transient Response ATX v3.1 Tests

[Note] For PSUs without a 12+4 pin connector, the maximum applied load for the transient response tests is 150%, rather than 200%.

transient_120_dev

transient_120_dev

transient_120_voltage

transient_120_voltage

transient_160_dev

transient_160_dev

transient_160_voltage

transient_160_voltage

transient_180_dev

transient_180_dev

transient_180_voltage

transient_180_voltage

transient_200_dev

transient_200_dev

transient_200_voltage

transient_200_voltage

The PSU passes all ATX v3.1 transient response tests.

transient_120_dev

transient_120_dev

transient_120_voltage

transient_120_voltage

transient_160_dev

transient_160_dev

transient_160_voltage

transient_160_voltage

transient_180_dev

transient_180_dev

transient_180_voltage

transient_180_voltage

transient_200_dev

transient_200_dev

transient_200_voltage

transient_200_voltage

The 12V rail’s performance is average in these tests.

Hold Up Time

Hold-up time is the interval for which output remains within its specified range after AC input is interrupted. It is measured in milliseconds and helps bridge very brief interruptions; it is not a substitute for a UPS or a guarantee of enough time for an operating-system shutdown.

hold_up_time

hold_up_time

ac_loss_hold_up_time

ac_loss_hold_up_time

pwr_ok_inactive_to_dc_loss_delay

pwr_ok_inactive_to_dc_loss_delay

The hold-up time is extended.

Inrush Current

Inrush current is the brief surge drawn at switch-on as the input capacitors charge. Lower peaks reduce stress on the input path and can help avoid nuisance breaker trips under the same supply conditions.

inrush_current_115V

inrush_current_115V

inrush_current_230V

inrush_current_230V

The inrush currents are at the expected levels, given the capacity of the unit’s bulk caps.

Leakage Current

Leakage current is current flowing through paths other than the intended functional circuit. In PSU testing, the measurement arrangement and the distinction between protective-conductor and touch current must be considered.

In an earthed PSU, EMI-filter Y capacitors contribute AC current to the protective conductor. The measured current depends on capacitance, input voltage, frequency and the test circuit, not simply on the number of capacitors.

The source cites IEC 62368-1 for its leakage and touch-current assessment. Compliance depends on the applicable equipment category and test conditions.

  • Normal Condition: Maximum touch current = 3.5 mA
  • Single Fault Condition: Maximum touch current = 10 mA

YT1200 PSU Review: Specifications and Power Performance

The leakage current is low.

PSU Timings

PSU timing tests check the sequence and duration of startup, power-good and shutdown signals against the stated ATX criteria. These should be read as measured timing behavior, not an independent guarantee against every system fault.

Alternative Low Power Modes concern low-power system operation and transitions between power states. The review examines their associated ATX timing requirements, including T1 and T3.

T1 and T3 Timings Explained

YT1200 PSU Review: Specifications and Power Performance

  • T1 (power-on time) measures the interval from PS_ON# assertion until the main outputs enter regulation. The subsequent PWR_OK delay is T3 and must be assessed separately. Apply the limits for the relevant ATX revision and low-power-mode requirements.
  • T3 (PWR_OK delay) is the interval from the outputs entering regulation until PWR_OK is asserted. It is distinct from T1. Compare results using the criteria for the same ATX revision and operating mode.
timing_20%_t1

timing_20%_t1

timing_20%_t3

timing_20%_t3

timing_100%_t1

timing_100%_t1

timing_100%_t3

timing_100%_t3

The PSU supports Alternative Low Power Modes.

Efficiency Normal, Light & Super-Light Loads

Efficiency is DC output power divided by AC input power. For example, delivering 400 W at 80% efficiency requires 500 W input, leaving 100 W as conversion loss.

avg_efficiency_normal_loads1_115V

avg_efficiency_normal_loads1_115V

avg_efficiency_normal_loads1_230V

avg_efficiency_normal_loads1_230V

avg_efficiency_low_loads1_115V

avg_efficiency_low_loads1_115V

avg_efficiency_low_loads1_230V

avg_efficiency_low_loads1_230V

efficiency_ultra_low_load1_115

efficiency_ultra_low_load1_115

efficiency_ultra_low_load1_230

efficiency_ultra_low_load1_230

Not so high average efficiency at normal loads, but the opposite applies to light and ultra-light loads.

Average Efficiency

The PSU’s average efficiency with more than 1450 different load levels at 115V and 230V is depicted in the graphs below.

avg_eff_115V

avg_eff_115V

avg_eff_230V

avg_eff_230V

The average efficiency meets the Cybenetics Platinum criteria.

Average PF

Power factor is real power in watts divided by apparent power in volt-amperes. It describes AC input-current behavior and is distinct from conversion efficiency. Active PFC aims to bring it closer to unity.

avg_pf_115V

avg_pf_115V

avg_pf_230V

avg_pf_230V

The APFC converter needs tuning for higher PF readings.

Average Efficiency 5VSB

5VSB_efficiency_115V

5VSB_efficiency_115V

5VSB_efficiency_230V

5VSB_efficiency_230V

The 5VSB rail’s efficiency is satisfactory.

Vampire Power

Standby input power is drawn while the PSU is connected to AC but not supplying the main system outputs. Functions such as +5VSB remain available. The measurement depends on the standby load and operating state.

Stand_By_115V

Stand_By_115V

Stand_By_230V

Stand_By_230V

Vampire power is below 0.1W at 115V, but notably above this threshold at 230V.

Protection Features

PSU protection tests examine responses to overload and other specified abnormal conditions. The presence of protection circuitry should be distinguished from its measured triggering thresholds and behavior.

OCP (Normal @ 29.8°C) 12V: 126.20A (126.20%), 12.120V 5V: 29.8A (149.00%), 4.992V 3.3V: 28.7A (143.50%), 3.363V 5VSB: 6.1A (203.33%), 4.973V
OCP (Hot @ 45.0°C) 12V: 117.60A (117.60%), 12.117V 5V: 29.8A (149.00%), 4.991V 3.3V: 28.7A (143.50%), 3.362V 5VSB: 6.4A (213.33%), 4.96V
OPP (Normal @ 29.3°C) 1525.99W (127.17%)
OPP (Hot @ 45.7°C) 1408.06W (117.34%)
OTP ✓ (145°C @ Heat Sink)
SCP 12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK Proper Operation
UVP (Full Load @ 90V) ✓
UVP (No Damage @ 80V) ✓
Conducted Emissions EN55032 & CISPR 32 ✗
NLO ✓
Fan Failure Protection ✗
SIP Surge: MOV Inrush: NTC & Bypass Relay

The OCP triggering points are conservative at 12V under both normal and hot conditions, and the difference between them is sufficiently high. The minor rails have high OCP triggering points, compared to the nominal ratings, and to make matters worse, there is no difference in the triggering points between normal and high temperatures. It is common knowledge that a power supply is stressed way more under high operating temperatures, so it is only natural to allow for lower amperage on all rails to protect it efficiently.

The reviewer considers OPP thresholds appropriately separated between normal and hot conditions. The other listed protections worked in the tests, but fan-failure protection was not implemented in the sample.

EMC Pre-Compliance at a Glance

The source evaluates electromagnetic emissions using CISPR 32/EN 55032 reference limits, including the stricter Class B limits associated with domestic equipment. These pre-compliance measurements do not by themselves establish complete regulatory certification.

Our equipment for EMI readings:

  • Rohde & Schwarz FPC1500 (loaded with all options)
  • Tekbox TBLC08 LISN
  • Tekbox TBFL1 transient limiter
  • Tekbox EMCview software
CISPR 32 / EN55032 Limits
CISPR 32 / EN 55032 Class A Conducted EMI Limit
Frequency of Emission (MHz) Conducted Limit (dBuV)
Quasi-peak Average
0.15 – 0.50 79 66
0.50 – 30.0 73 60
CISPR 32 / EN 55032 Class B Conducted EMI Limit
Frequency of Emission (MHz) Conducted Limit (dBuV)
Quasi-peak Average
0.15 – 0.50 66 – 56 56 – 46
0.50 – 5.00 56 46
5.00 – 30.00 60 50

The review applies the 4 dB margin described in its ATX emissions criteria. Passing that comparison should not be confused with independently demonstrating compliance with every applicable EMC limit.

EMI Results

YT1200 PSU Review: Specifications and Power Performance

EMI pre-compliance results exceeded the reference limits used in this review.

Average Noise

avg_noise_115V

avg_noise_115V

avg_noise_230V

avg_noise_230V

The PSU’s average noise output is increased.

Fan Noise & Speed Maps @ 28-32 °C – 115V

CL_Fan_Noise

CL_Fan_Noise

CL_Fan_Speed

CL_Fan_Speed

The fan speed profile map looks like a modern abstract art painting. The fan’s passive mode lasts up to 420W at 12V, with the load on the minor rails remaining below 70W. At loads up to 420W, if you apply more than 70W to the minor rails, the fan’s speed increases, raising the noise level to 10-15 dBA, which is not particularly high. For loads above 420W, the fan’s noise exceeds 25 dBA when more than 70-75W are applied to the minor rails. The 30 dBA mark is reached at around 680W, and the fan spins at higher speeds from 680W to 1030W, occasionally exceeding 40 dBA, with more than 90W on the minor rails. Lastly, with more than 1030W, you will be treated to over 45 dBA noise.

Fan Noise & Speed Maps @ 28-32 °C – 230V

CL_Fan_Noise

CL_Fan_Noise

CL_Fan_Speed

CL_Fan_Speed

At 230V, the fan speed profile is identical to that of the 115V input, with the only significant difference being the break at 200W, where the fan’s noise increases to the 10-15 dBA region.

Overall Performance

Here is the link to read more about this performance algorithm.

perf_115V

perf_115V

perf_230V

perf_230V

The overall performance is decent, but there is a notable difference from the top performers in the 1200W category.

Epilogue

The reviewer found good regulation, ripple suppression, inrush control and hold-up time on the Andyson platform. Reservations concern soldering, APFC power factor especially at 230 V, minor-rail OCP thresholds and EMI pre-compliance results. The sample's good results in some areas do not remove those separate limitations.

Noise rises not only with +12 V demand but also with heavy loading of the minor outputs. The reviewer attributes this to cooling needs on the DC-to-DC daughterboard. A high combined +5 V load, including lighting devices, can therefore affect the fan profile even when +12 V is not heavily loaded. EMI performance was a separate concern in this sample.

All in all, the CPS PCCOOLER YT1200 offers decent overall performance, but since I don’t have any pricing information (at the time of the review), I cannot comment on its price-per-performance ratio.

YT1200 PSU Review: Specifications and Power Performance

The original reviewer links to a comparison of ATX v3.x power supplies and discloses that purchases through affiliate links may earn a commission without changing the listed price. (Reference 1)

Buy CPS PCCOOLER YT1200 ATX v3.1 Buy Montech Century II 1200W Buy NZXT C1200 Buy ASUS ROG Thor 1200W Platinum II Buy SilverStone HELA 1200R Platinum Buy Montech Titan Gold 1200W Buy Enermax Revolution D.F. 2 1200W Buy Thermaltake Toughpower GF3 1200W Buy FSP Hydro PTM PRO 1200W ATX 3.0 Buy DeepCool PX1200G Buy FSP Hydro PTM X PRO 1200W Buy be quiet! Straight Power 12-1200w Buy be quiet! Pure Performance Power 12 M 1200W Buy Seasonic Vertex GX-1200 Buy Thermaltake Toughpower PF3 1200W Buy Thermaltake Toughpower GF A3 1200W Buy Corsair RM1200x Shift

Article source: Hardware Busters

Original review link: https://hwbusters.com/psus/pccooler-yt1200-atx-v3-1-psu-review/

Weibo