Review of the CPS PCCOOLER YT1200 power supply
The YT range includes 850 W, 1000 W and 1200 W models with Cybenetics Platinum efficiency certification. This review examines the 1200 W version for demanding gaming and work systems.
Specifications, design and price (Reference 1; Reference 2)
The source reports Platinum-level efficiency and Cybenetics-tested ATX 3.1 support. The +12 V output is rated for the full 1200 W, while +3.3 V and +5 V share a 100 W limit. Combined output remains subject to the PSU's total rating.
The YT1200 is reported here with a 150 mm-deep body and 135 mm fan. A switch selects semi-passive or continuous-fan operation.
Besides a 600 W-marked 12V-2×6 socket, the panel has five CPU/PCIe cable sockets and three peripheral-cable sockets. Use only the supplied or explicitly compatible cables.
| Cable type | Number of cables | End connectors on the cable | Length to first connector, mm | Conductor cross-section |
|---|---|---|---|---|
| 24-pin | 1 | 1 | 600 | 16AWG |
| EPS12V | 2 | 1 (2 × ATX12V) | 650 | 16AWG |
| 12V-2x6 | 1 | 1 | 650 | 16/24AWG |
| PCI Express (6+2) | 3 | 1 | 600 | 16AWG |
| SATA + Molex | 2 | 4 × SATA | 450 | 18AWG |
| SATA + Molex | 1 | 3 × SATA + 1 × Molex | 450 | 18AWG |
Most power cables use 16 AWG conductors; the three SATA/Molex cable assemblies use a smaller gauge for their lower-current role. Flat, textured insulation helps routing. Cable ties and a tester are also supplied. The conductors were not attracted to a magnet in the reviewer's check.
During preparation of the review, the lowest observed Russian retail price was RUB 13,999. The source lists a ten-year manufacturer warranty.
Internal design (Reference 1; Reference 2)
The YT1200 uses an Andyson OEM platform.
The input has a two-stage EMI filter, fuse, MOV surge protection and an NTC with bypass relay to limit inrush current.
The main stage uses a full-bridge LLC topology. Synchronous rectification supplies +12 V, while DC-to-DC converters generate +3.3 V and +5 V.
Electrolytic capacitors are manufactured by Japanese companies Nippon Chemi-Con and Rubycon, as well as Taiwanese Teapo.
The 135 mm Hong Hua fan uses a fluid-dynamic bearing.
Test method (Reference 1; Reference 2)
Equipment:
- multi-channel electronic load PSU-Test-950W from the MicroDip company: four channels with a current up to 30 A for lines 12, 5 and 3.3 V, a channel with a current up to 5 A for the standby power line 5 V (maximum total power - 994 W);
- Tonghui TH8300 electronic load chassis and Tonghui TH8305-80-80 modular load with 500 W capacity for 12 V line;
- power meter GW Instek GPM-78213;
- OWON VDS1022I oscilloscope;
- high-voltage insulated differential probes Hantek HT8050;
- resistive (so-called Z0) probes: coaxial cable RG-58, resistor 455 Ohm in series, final termination 50 Ohm;
- Ippon Innova RTB 3000 UPS in constant frequency mode as a quasi-reference power supply (U ≈ 230 V, f ≈ 50 Hz, crest factor ≈ 1,45, THD ≈ 1,48 %). There are no other consumers connected to the UPS other than the device under test;
- laser tachometer DT2234A.
The method for multi-output ATX supplies includes the following tests.
Standby mode
PS_ON# is inactive, with no external load on the +5 V standby rail.
Measured parameters:
- efficiency;
- power factor.
Loading the +5 V standby rail
With PS_ON# inactive, the +5 V standby load is increased from 1 W to its specified maximum in 1 W steps.
Measured parameters:
- efficiency;
- power factor;
- voltage of the standby power line 5 V.
The source uses a ±5% voltage tolerance for +5 V standby.
Cross-load testing
Different combinations of load on +12 V, +5 V and +3.3 V are applied to evaluate output behavior under an uneven distribution of demand.
- maximum current of each line (excluding standby power line 5 V) without load on other lines;
- maximum total power of small lines 3,3 and 5 V at the maximum current of one of them and the maximum current of the standby power line 5 V. The remainder of the total power of the device under test is exhausted due to the load on the 12 V line;
- the power of the 12 V line varies from 0 to a maximum in steps of 100 W, and the total power of lines 5 and 3.3 V - from 0 to a maximum in steps of 20 W. The currents of the 5 and 3.3 V lines are equal. Additional steps may be introduced to achieve maximum power.
Measured parameters:
- efficiency;
- power factor;
- fan rotation speed of the device under test (if the power supply has a semi-passive cooling mode, it always turns on);
- line voltage.
The source's ATX 3.0-and-later criteria allow −7% to +5% on +12 V and ±5% on +5 V and +3.3 V.
DC voltage ripple
Testing is performed under the following conditions (within the specifications of the device under test and electronic loads):
- maximum current of each line (excluding standby power line 5 V) without load on other lines;
- maximum total power of small lines 3,3 and 5 V at the maximum current of one of them and the maximum current of the standby power line 5 V. The remainder of the total power of the device under test is exhausted due to the load on the 12 V line.
Peak-to-peak ripple is measured with a 26 MHz oscilloscope and resistive probes. Each measured output has a 10 µF electrolytic and a 0.1 µF ceramic capacitor connected in parallel with the load.
The maximum peak-to-peak ripple observed under the test conditions is reported. The method uses limits of 120 mV on +12 V and 50 mV on the other outputs.
Hold-up time after loss of AC input
With +12 V and the combined minor outputs at their specified test loads, AC input is disconnected. The oscilloscope measures the interval until +12 V falls to the minimum accepted level of 11.16 V.
The source describes a 12 ms full-load requirement under ATX 3.1 and a recommended 17 ms at 80% rated load. Earlier versions through ATX 3.0 used a 17 ms full-load requirement. Results should be compared at the corresponding load.
Fan speed
Fan speed is recorded during cross-load tests after it stabilizes at each load setting.
Sources
- ATX Version 3 Multi Rail Desktop Platform Power Supply Design Guide;
- Intel Desktop Platforms Power Supply Test Plan;
- The Complete Cybenetics Test Protocol, Including Energy Efficiency, Output Noise, And Overall Performance Calculation of AC-DC Power Supplies.
The linked article on power-supply design and test methods explains the components and how the results should be interpreted. (Reference 1)
Test results (Reference 1; Reference 2)
Standby mode
Standby input power was 0.3 W. The author notes that this was above many supplies tested in the previous year, but still acceptable in practice.
| Standby mode | |
|---|---|
| P (⏦), W | λ |
| 0,314 | 0,006 |
+5 V standby
The +5 V standby output showed good regulation and efficiency in this test.
| Emergency power supply 5 V | ||||||
|---|---|---|---|---|---|---|
| P (set), W | U, V | I, A | P (⎓), W | P (⏦), W | Efficiency, % | λ |
| 5 | 5,08 | 0,95 | 4,88 | 6,60 | 74 | 0,11 |
| 10 | 5,06 | 1,95 | 9,86 | 12,65 | 78 | 0,12 |
| 15 | 5,03 | 2,95 | 14,82 | 19,00 | 78 | 0,30 |
Efficiency and power factor
Peak efficiency was approximately 93%. The reviewer found power factor less impressive, particularly with a high share of load on the minor outputs. Efficiency and power factor are separate measurements.
Voltage regulation
Voltage regulation was good across the outputs. Only +5 V deviated by more than 2%, while remaining within the source's stated ATX tolerance.
| Cross load (maximum line power) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P (set), W | 3.3 V | 5 V | 12 V 1 | 12 V 2 | 12 V 3 | Standby +5VSB | P (⎓), W | P (⏦), W | Efficiency, % | λ | Fan, rpm | ||||||
| U, V | I, A | U, V | I, A | U, V | I, A | U, V | I, A | U, V | I, A | U, V | I, A | ||||||
| 66 | 3,30 | 19,70 | 5,00 | 0,00 | 11,99 | 0,00 | 12,00 | 0,00 | 0,00 | 0,00 | 5,10 | 0,00 | 65,03 | 88,90 | 73 | 0,54 | 621 |
| 100 | 3,35 | 0,00 | 4,88 | 19,72 | 11,99 | 0,00 | 12,00 | 0,00 | 0,00 | 0,00 | 5,10 | 0,00 | 96,19 | 122,00 | 79 | 0,64 | 623 |
| 1 200 | 3,35 | 0,00 | 5,00 | 0,00 | 11,92 | 29,45 | 11,99 | 29,51 | 12,14 | 40,00 | 5,06 | 0,00 | 1 190,32 | 1 297,00 | 92 | 0,96 | 1 844 |
| 1 200 | 3,29 | 19,70 | 4,94 | 6,65 | 11,93 | 29,45 | 12,00 | 29,51 | 12,17 | 30,43 | 4,95 | 2,95 | 1 188,13 | 1 310,00 | 91 | 0,98 | 1 846 |
| 1 200 | 3,34 | 0,00 | 4,86 | 19,72 | 11,93 | 29,45 | 12,00 | 29,51 | 12,17 | 30,43 | 4,95 | 2,95 | 1 186,42 | 1 300,00 | 91 | 0,96 | 1 847 |
| Cross load (all tests) | ||||||
|---|---|---|---|---|---|---|
| 3.3 V | 5 V | 12 V | Standby +5VSB | Efficiency, % | λ | |
| U, V | U, V | U, V | U, V | |||
| Max. | 3,35 | 5,00 | 12,17 | 5,10 | 93 | 0,98 |
| Avg. | 3,33 | 4,96 | 12,03 | 5,03 | 90 | 0,88 |
| Min. | 3,29 | 4,86 | 11,92 | 4,95 | 73 | 0,26 |
Peak-to-peak ripple
Ripple stayed comfortably inside the test's allowable limits.
| Voltage ripple range | ||||||||
|---|---|---|---|---|---|---|---|---|
| P (set), W | 3.3 V | 5 V | 12 V | Standby +5VSB | ||||
| I, A | Vpp, mV | I, A | Vpp, mV | I, A | Vpp, mV | I, A | Vpp, mV | |
| 66 | 19,70 | 12 | 0,00 | 22 | 0,00 | 24 | 0,00 | 36 |
| 100 | 0,00 | 16 | 19,72 | 20 | 0,00 | 24 | 0,00 | 34 |
| 1 200 | 0,00 | 26 | 0,00 | 24 | 98,96 | 20 | 0,00 | 38 |
| 1 200 | 19,70 | 16 | 6,65 | 18 | 89,39 | 20 | 2,95 | 28 |
| 1 200 | 0,00 | 24 | 19,72 | 20 | 89,39 | 20 | 2,95 | 28 |
Hold-Up Time
Under the stated maximum +12 V load, voltage remained acceptable for 24.5 ms after AC loss, exceeding the minimum criterion used by the review.
Fan speed
The fan remained stopped up to approximately 400 W in the test. At 500–700 W it ran no faster than about 600 RPM, reaching roughly 1800 RPM at loads of 1.1 kW and above.
| Fan rotation speed, rpm | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power 3.3 V + 5 V, W | 120 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| 100 | 620 | 602 | 603 | 603 | 599 | 922 | 923 | 923 | 1 483 | 1 481 | 1 478 | N/A | 1 845 | |
| 80 | 588 | 589 | 592 | 1 195 | 1 196 | 1 192 | 1 840 | 1 843 | ||||||
| 60 | 591 | 594 | 594 | 1 196 | 1 194 | 1 192 | 1 840 | 1 844 | ||||||
| 40 | 593 | 597 | 594 | 1 194 | 1 193 | 1 194 | 1 846 | 1 845 | ||||||
| 20 | 594 | 593 | 594 | 1 190 | 1 189 | 1 189 | 1 841 | 1 844 | ||||||
| 0 | 593 | 592 | 589 | 1 180 | 1 182 | 1 186 | 1 842 | 1 844 | ||||||
| 0 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 | 1 000 | 1 100 | Max. | ||
| Power 12 V, W | ||||||||||||||
Conclusion (Reference 1; Reference 2)
The reviewer praises the full-bridge platform, substantial cables, fan and stated ten-year warranty. The internal inspection lists Japanese capacitors alongside Teapo parts. Power factor and the conservative fan-control profile were the main reservations; this was not considered the quietest supply in its class.
Article source: 3DNews
Original review link: https://3dnews.ru/1146806/obzor-pccooler-yt1200