Review of the CPS PCCOOLER YK750 power supply unit: modern and inexpensive
The CPS PCCOOLER YK750 (P5-YK750-B1F) is a relatively affordable 750 W PSU. This review examines its construction and measured behaviour.
At publication, the source quoted just over ₴2600, a five-year warranty and a native graphics-power connector. The following inspection and tests assess these features in context; prices and regional terms may change.
Specification
|
Model |
CPS PCCOOLER YK750 (P5-YK750-B1F) |
|
Type |
ATX12V 3.1 |
|
Maximum power, W |
750 |
|
Power on channel +12 V, W |
750 |
|
The power of the +3.3 V and +5 V lines, W |
100 |
|
Number of lines +12 V |
1 |
|
The maximum current of the channel +3.3 V, A |
18 |
|
The maximum current of the channel +5 V, A |
18 |
|
The maximum current of the channel +12 V, A |
62,5 |
|
The maximum current of the channel -12 V, A |
0,3 |
|
The maximum channel current is +5Vsb (main power supply line), A |
3,0 |
|
Input voltage, V |
100 − 240 |
|
Input current, A |
4,5 − 9 |
|
Holding time at 75% load, ms |
≥16 |
|
Efficiency, % |
≤88 |
|
80 PLUS certification |
Bronze |
|
Power factor compensation method |
Active |
|
Power factor (PF), % |
≤98 |
|
PCIe-connectors |
4 (6+2-contact) |
|
Connector PCIe 5.0 (12VHPWR) |
1 (450 W) |
|
Modular |
No |
|
Dimensions of the fan, mm |
135 x 135 x 25 |
|
Fan bearing type |
Improved Bushing (HYB) |
|
Protect |
OPP, OVP, UVP, OCP, OTP, SCP |
|
Working time for failure, h |
100000 |
|
Dimensions (L x W x H), mm |
150 x 150 x 86 |
|
Warranty, years |
5 |
|
Manufacturer's website |
|
|
Device page |
Packaging and delivery kit
The model-specific box lists specifications, output ratings and connectors, with a link to the manufacturer's site. (Reference 1)
The PSU is part of Shenzhen Fluence Technology PLC's CPS PCCOOLER component range, with the manufacturer's logos on the box and enclosure.
Accessories include an AC cable, mounting screws, disposable cable ties and documentation.
Appearance
The 135 mm fan sits in a 150 × 150 × 86 mm body.
Triangular perforations form the fan intake rather than a wire grille or conventional honeycomb.
Smaller triangular openings cover the rear, beside the AC inlet and power switch.
The bottom and rear use a large proportion of their area for ventilation.
Decorative triangles and an orange brand mark continue the side-panel design.
The +12 V rail is rated for the full 750 W; +3.3 V and +5 V share a 100 W combined limit. The unit lists 80 PLUS Bronze and a 100–240 V input range. Total simultaneous output must remain within 750 W.
Fixed output cables leave through a protected round opening.
Most conductors are 18 AWG; the native graphics-power cable uses thicker 16 AWG wires.
The complete configuration of the cable system is as follows:
|
Types of connectors |
Number |
The length of the wires to the connector (connectors), see |
Caliber |
|
20+4-contact ATX |
1 |
55 |
18 AWG |
|
4+4-contact ATX12V |
2 |
65 |
18 AWG |
|
two 6+2-contact PCIe |
2 |
50-64 |
18 AWG |
|
one PCIe 5.0 (450 W) |
1 |
50 |
16 AWG |
|
three SATA + one PATA |
2 |
45-60-75-90 |
18 AWG |
Main connections are one 20+4-pin ATX and two 4+4-pin CPU plugs.
Graphics connections comprise one 450 W-rated 12VHPWR and four 6+2-pin PCIe plugs. Two peripheral cables provide six SATA and two legacy PATA plugs. Connector totals do not increase the PSU's overall output rating.
Internal structure
With the appearance, everything is clear, so now it's time to look "under the hood".
A 135 mm PowerYear PY S13525M12S uses an enhanced sleeve bearing and a 2-pin connection. Its 12 V/0.38 A label corresponds to 4.56 W electrical input.
Three finned heatsinks cool the bridge rectifier, primary/APFC devices and secondary power components.
The input filter includes chokes, capacitors, a fuse and a surge-limiting varistor.
The input rectifier is heatsink-mounted. Nearby are the APFC choke and bulk capacitor.
The input capacitor is an Ltec 470 µF part rated at 85°C. Capacitance alone does not establish hold-up time or reliability.
This affordable design uses separate output regulation rather than group regulation, without DC-DC conversion for the minor rails.
The output filter uses high-temperature JunFu electrolytics and PolyCap polymer capacitors.
...just like the transistors used here (for example, PW022N06CS).
A Grenergy GR8329E supervisor supports the protection functions listed below. A component's presence does not by itself verify every trip threshold.
- from increased output voltage (OVP);
- from low output voltage (UVP);
- from short circuit (SCP);
- from power overload (OPP);
- from overload according to the current of each channel (OCP);
- from overheating (OTP);
- from inrush currents (SIP).
Cross-load characteristics
The review uses ±5% as the voltage-tolerance criterion for the main rails.
The following cross-load results show deviations from each rail's nominal voltage.
- line +3.3 V: from -4% to +2%;
- line +5 V: from -2% to +2%;
- line +12 V: from +1% to +2%.
All measured deviations lay between −4% and +2%, within the stated ±5% criterion.
Noises and pulsations in the entire voltage range
Peak-to-peak ripple is compared with 50 mV limits on +3.3 V/+5 V and 120 mV on +12 V.
- lines +3.3 V and +5 V: 50 mV;
- line +12 V: 120 mV.
Ripple stayed within 50 mV on all three main rails, comfortably below the cited +12 V limit.
The next power line + 5VSB
The +5VSB standby rail varied from 5.10 to 5.02 V, or +2% to +0.4% of nominal.
PFC
Table showing the change of PFC depending on the load of the power supply:
|
Load, W |
75 |
150 |
200 |
300 |
400 |
500 |
600 |
650 |
750 |
|
Load*, % |
10 |
20 |
27 |
40 |
53 |
67 |
80 |
87 |
100 |
|
PFC |
0,82 |
0,92 |
0,94 |
0,96 |
0,96 |
0,97 |
0,98 |
0,98 |
0,98 |
Load* – load as a percentage of the nominal power of the power supply unit.
Power factor reached 0.92 at the reported 150 W point and peaked at 0.98. Power factor is distinct from conversion efficiency.
efficiency
The cited 230 V Bronze thresholds are 85%, 88% and 85% at 20%, 50% and full load. The first two measured points met them; full-load efficiency was lower at 82.7%. This bench comparison is not a certification test.
Cooling system and temperature regime
Through 300 W, fan speed was about 620–780 rpm and subjectively very quiet. Around 400 W/1300 rpm it remained quiet, with noise rising further as load increased.
After 15 minutes at 700 W, the main transformer reached about 85°C. This is a short-term temperature observation, not proof of long-term thermal safety or lifetime.
Practical tests on a real configuration
The real-system test used a stock Core i7-11700K and Palit GeForce RTX 4070 Ti GameRock OC, with the graphics-card power rating above 285 W.
|
Component |
Model |
|
Processor |
Intel Core i7-11700K (Socket LGA1200, 8 cores / 16 threads, 3,6 – 5.0 GHz, 125 W TDP), 1.25 V |
|
Cooler |
DeepCool LT520 WH |
|
Motherboard |
ASRock Z590 STEEL LEGEND (Intel LGA 1200, Z590, ATX) |
|
RAM |
2 x DDR4-3600 16 GB Kingston FURY Beast RGB (KF436C18BBAK2/32) |
|
Video card |
Palit GeForce RTX 4070 Ti GameRock OC |
|
SSD |
Kingston KC600 512 GB (SKC600/512G) |
|
Wattmeter |
Seasonic PowerAngel |
|
Multimeter |
MASTECH MY64 |
Idle and maximum-load modes used AIDA FPU and GPU stress tests. Seasonic PowerAngel measured wall input, while a MASTECH MY64 measured +12 V, +5 V and +3.3 V. AC input is not the same as PSU DC output.
The measured rail voltages are listed below.
|
Regime |
Velychyna, V |
Deviation, % |
|
+12 V |
||
|
Idle |
12,3 |
2,5 |
|
Burn |
12,4 |
3,3 |
|
+5 V |
||
|
Idle |
5,14 |
2,8 |
|
Burn |
5,14 |
2,8 |
|
+3.3 V |
||
|
Idle |
3,39 |
2,7 |
|
Burn |
3,38 |
2,4 |
|
Input power consumption, W |
||
|
Idle |
74 |
|
|
Burn |
618 |
|
In this system, all measured rails stayed above nominal, with deviations of about +2.4% to +3.3%. The result applies to the tested load distribution.
The tested Core i7/RTX 4070 Ti system ran successfully. Suitability for another Core i5 or Ryzen 5 build still depends on the actual GPU, total load and connectors, not the CPU family name alone.
Power consumption when the computer is idle and turned off
The complete test system drew about 2 W when off and 3 W in sleep. These are system-level observations, not isolated PSU standby losses.
Result
The YK750 stands out through its triangular case styling, stated five-year warranty and 450 W-rated native 12VHPWR connection. These features are useful context for its price class.
The lower price is reflected in conventional separate regulation without DC-DC and the component selection. Measured voltage behaviour was acceptable, but component country of origin alone cannot establish quality.
Overall, YK750 offers useful connectors and acceptable output behaviour at a moderate price. Noise and heating were reasonable in this test, while the full-load efficiency shortfall should remain part of the buying decision.
Advantages:
- good level of efficiency (80 PLUS Bronze);
- separate voltage stabilization;
- good state of voltage on the main power lines;
- no voltage sag when connected to a powerful configuration;
- availability of all types of protection;
- the possibility of operation in a wide range of network voltage (from 100 to 240 V);
- easy-to-lay flat cables-loops;
- four 6+2-contact connectors PCIe and one 450-W PCIe 5.0;
- 135-mm fan on an improved sleeve;
- effective cooling system;
- very quiet operation under load up to 300 W;
- 5 years of warranty.
Features:
- the element base contains Taiwanese electrolytic capacitors, as well as Chinese polymers and transistors.
Author: Oles Pakholok
The source thanks IT-Link for providing the review sample. (Reference 1)
Article source: GECID
Original review link: https://ua.gecid.com/power/pccooler_yk-750/